page 3
3. Installation Preparation.
ON
OFF
ON
OFF
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to the
OFF position.
WARNING:
Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING:
When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and
can support the full weight of the fan. Ensure the outlet box is
clearly marked "Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do so can
result in serious injury.
CAUTION
: Be sure outlet box is grounded and that a ground
wire (
GREEN
or bare) is present.
Install hanging bracket to outlet box using original screws,
spring washers and flat washers provided with new or
original outlet box.
*
Arrange electrical wiring around the
back of the hanging bracket and away from the bracket
opening.
*Note
: It is very important that you use the proper hardware
when installing the hanging bracket as this will support the
fan.
downrod
installation
flushmount
installation
10 feet
(3.05m) (76cm)
30
inches
12f
t.
- 20f
t.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66m - 6.1m)
blade edge
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 10 feet (3.05m) from the floor and
30in. (76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a
downrod
on a
regular (no-slope) ceiling
only
. The hanging
length can be extended by purchasing a longer
downrod (0.5in./1.27cm diameter). Fan
cannot
be installed as a flushmount or on a vaulted
ceilling.
Installation requires these tools:
Phillips screwdriver, flathead screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape
hanging bracket
spring washers
outlet box screws
flat washers
CANNOT be
installed on
angled or
vaulted ceilings