background image

page 3

3. Installation Preparation.

ON

OFF

ON

OFF

4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the 
OFF position. 

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure and 
can support the full weight of the fan. Ensure the outlet box is 
clearly marked "Suitable for Fan Support." If not, it must be 
replaced with an approved outlet box. Failure to do so can 
result in serious injury.

CAUTION

: Be sure outlet box is grounded and that a ground 

wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original screws, 
spring washers and flat washers provided with new or 
original outlet box.

Arrange electrical wiring around the 

back of the hanging bracket and away from the bracket 
opening.

*Note

: It is very important that you use the proper hardware 

when installing the hanging bracket as this will support the 
fan. 

downrod

installation

flushmount

installation

10 feet

(3.05m) (76cm)

30 

inches

12f

t.

  - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

blade edge

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 10 feet (3.05m) from the floor and 
30in. (76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400  
square feet (37.2 square meters).

This fan can be mounted with a 

downrod 

on a 

regular (no-slope) ceiling 

only

.  The hanging 

length can be extended by purchasing a longer 
downrod (0.5in./1.27cm diameter). Fan 

cannot

 

be installed as a flushmount or on a vaulted 
ceilling.

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape

hanging bracket

spring washers

outlet box screws

flat washers

CANNOT be
installed on
angled or
vaulted ceilings

Summary of Contents for K10444

Page 1: ...y pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pgs 5 6 Canopy Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly pgs 7 8 Handheld Remote Control A...

Page 2: ...conductor on opposite sides of the outlet box WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device or control fan speed with a full rang...

Page 3: ...iece h glass shade cage pre attached to light kit fitter 1 piece i yoke cover 1 piece j blade arm 5 pieces k rubber washer pre attached to light kit fitter 1 piece l hex nut pre attached to light kit...

Page 4: ...ical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support...

Page 5: ...ty cable and electrical wires through threaded end of downrod and pull extra wire slack from the upper end of the downrod Refer to diagram 2 Thread downrod into the motor housing yoke until holes for...

Page 6: ...ap each wire connector separately with electrical tape as an extra safety measure black black white white black supply wire ground green or bare white supply wire from ceiling from fan ground green or...

Page 7: ...canopy Align holes in anti sway adapter with holes on underside of canopy and then re insert the screws that were previously removed Tighten both screws securely Slide canopy up to anit sway adapter...

Page 8: ...using aligning holes in blade arm with holes located on the underside of the motor housing refer to drawing at right Attach blade arm with blade arm screws lock washers Before securing screws permanen...

Page 9: ...e insert screw that was previously removed and securely tighten all 3 screws with Phillips screwdriver Install 3 candelabra base 4 watt LED bulbs included Important When replacing bulbs please allow g...

Page 10: ...ll control as possible Refer to diagram 2 Install one battery included in wall control Refer to diagram 2 The dimmer switch labeled DIM and ON has been pre set to the ON position DIM If you do not wis...

Page 11: ...fan Restore electrical power and then if using wall control set slider switch on wall control to the ON position Within 60 seconds of turning on the wall control press and hold the fan SET button on t...

Page 12: ...ote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting secti...

Page 13: ...k to be sure set screw s on motor housing yoke is are tightened securely 3 Check to be sure set screw on hanging ball is tightened securely Warranty WARNING Failure to disconnect power supply prior to...

Reviews: