background image

page 10

13. Testing Your Fan.

12. Remote Control Operation.

ON/OFF

 slider switch - turns 

wall control

 ON or OFF 

(switch not functional on handheld remote)

HIGH

 button - turns 

fan

 to HIGH speed

MED

 button - turns 

fan

 to MEDIUM speed

LOW

 button - turns 

fan

 to LOW speed

OFF

 button - turns 

fan

 OFF

L1

 button - (not applicable for this fan)

L2 

button -

 

turns 

light kit

 ON/OFF when pressed once; 

dims 

light kit

 when pressed and held down

REV

 button - used to REVERSE blade direction 

(fan must be set on 

low

 

before

 reversing blade 

direction)

1

1

-

2

2

-

wall control

1

1

-

2

2

-

CAUTION

:

 The wall and/or handheld remote control can be programmed 

to multiple receivers or fans. If this is not desired, turn wall switch off to any 
other programmable receiver or fan.

Restore electrical power and then, if using wall control, set slider switch 
on wall control to the ON position. Within 60 seconds of turning on the 
wall control, press and hold the fan 

OFF

 button on the wall control for 

5 seconds or until light blinks twice.

Turn power off again for at least 5 seconds

 and then turn power back 

on. Within 60 seconds of restoring the power, press and hold the fan 

OFF

 button on the front of the handheld remote control for 5 seconds 

or until light blinks twice.

Test the light and fan functions to confirm the learning process is 
complete--

see Section 13 below.

handheld

remote control

It is recommended that you test fan before finalizing 
installation. Restore power from circuit box and light switch (if 
applicable). Test wall control (optional installation) by locating 
ON/OFF slider switch on wall control, then set to the ON 
position. Test light and dimmer function and then test fan 
speeds. Next, locate handheld remote control. Test the light 
ON/OFF function by pressing the L2 button; test the dimmer 
function by pressing the L2 button and holding it down for 
1 second. Test fan speeds with the different fan speed buttons. 
If the wall and/or handheld remote control operates all of the 
functions of the fan, battery has been installed correctly. If the 
wall and/or handheld remote control do (does) not operate all 
of the fan/light functions, refer to "Troubleshooting" section to 
solve any issues before contacting Customer Service.

Fan 

must

 be on LOW 

before

 setting the fan to reverse direction. 

Use "reverse" button to recirculate air depending on the season.

NOTE

: If the wall control/handheld remote control interferes 

with other appliances, go back to the instructions in Section 11 
above.

11. Automated Learning Process./Activating Code.

1

1

-

2

2

-

Summary of Contents for FB60OBG5

Page 1: ...g Process Activating Code pg 10 Remote Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement pg 11 net weight of fan 32 6 lb 14 8 kg PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE For Damp Location For Model FB60OBG5 Federal regulations require ceiling fans with light kits manufactured or imported after January 1 2009 to limit ...

Page 2: ...fan lead wires consult an electrician for the proper size wire connectors to use WARNING If using this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL C...

Page 3: ...trol 2 pieces f plate 1 piece g remote control cover 1 piece h faceplate 3 pieces i motor housing 1 piece j yoke cover 1 piece k canopy cover in hardware pack 1 piece l glass shade 1 piece m light kit fitter 1 piece n threaded washer pre attached to light kit fitter 1 piece o finial plate pre attached to light kit fitter 1 piece p finial pre attached to light kit fitter 1 piece q blade 5 pieces r ...

Page 4: ...6cm 30 inches flat washers Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can suppor...

Page 5: ... Refer to diagram 2 Locate canopy cover in hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with shiny side toward the motor housing Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw I...

Page 6: ... with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to help lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood screw washer and lock washer not supplied with the safety ca...

Page 7: ...IMPORTANT Wall control will not function unless battery is installed Since this fan comes with a halogen bulb the dimmer switch labeled DIM and ON OFF has been pre set to the ON position DIM If you do not wish to have dimming capability please move the switch to the OFF position ON OFF Select a faceplate almond or white and press firmly onto front of wall control Attach wall control to outlet box ...

Page 8: ...ar page 7 8 Blade Assembly motor housing blade plate blade attachment screws and washers blade 7 Canopy Assembly Locate 2 screws on underside of hanging bracket and remove screw closest to the open end of the hanging bracket Partially loosen the other screw Lift canopy to hanging bracket Place rounded part of slotted hole in canopy over loosened screw in hanging bracket and push up Twist canopy to...

Page 9: ...tall 3 candelabra base 60 watt max bulbs included Important When replacing bulbs please allow bulbs and glass shade to cool down before touching Remove finial finial plate and threaded washer from threaded rod on light kit fitter and save for later use Align hole in glass shade with threaded rod and push up gently until threaded rod comes through hole Secure glass shade with threaded washer that w...

Page 10: ... have dimming capability please move the switch to the OFF position ON OFF Refer to diagram 2 Attach black faceplate to front of wall control press down firmly Refer to diagram 3 Align holes in wall control with posts located on inside of TOP part of remote control cover and press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control co...

Page 11: ...f the handheld remote control for 5 seconds or until light blinks twice Test the light and fan functions to confirm the learning process is complete see Section 13 below handheld remote control It is recommended that you test fan before finalizing installation Restore power from circuit box and light switch if applicable Test wall control optional installation by locating ON OFF slider switch on w...

Page 12: ...expressed or implied whatsoever This limitation as to consequential damages shall not apply in states where prohibited page 11 Problem Fan fails to operate Solutions 1 Check wall switch to fan wall control 2 Check to be sure wall control optional use is wired properly 3 Check to be sure fan is wired properly 4 Learning process between fan handheld remote control and if applicable wall control may ...

Page 13: ...o Pág 10 Funcionamiento del control remoto Pág 10 Verificación del funcionamiento del ventilador Pág 10 Localización de fallas Pág 11 Garantía Pág 11 Piezas de repuesto Pág 11 IMPRESO EN CHINA LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA UTILIZACION FUTURA peso neto del ventilador 14 8 kg 32 6 lb REGISTRADO PARA LUGAR HUMEDO For Damp Location Para modelo FB60OBG5 Guía de instalación El reglamento fe...

Page 14: ... del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tamaño correcto de conectores para cable que se debe usar ADVERTENCIA Si va a utilizar este ventilador en un lugar HUMEDO hay que conectar el ventilador a un circuito de alimentación que esté protegido por un Interruptor de Circuito de Falla de Tierra GFCI por sus siglas en inglés para reducir el ri...

Page 15: ...tapa 3 unidades i bastidor del motor 1 unidad j cubierta del cuello 1 unidad k tapa de la cubierta decorativa en paquete de artículos de ferretería 1 unidad l pantalla de vidrio 1 unidad m conectador para el juego de luz 1 unidad n arandela con rosca fijada de antemano al conectador para el juego de luz 1 unidad o placa del adorno con rosca fijada de antemano al conectador para el juego de luz 1 u...

Page 16: ... VERDE o pelado Instalar el soporte de montaje utilizando los tornillos originales las arandelas de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalación en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado eléctrico los cables en la parte de atrás del soporte y lejos de la abertura d...

Page 17: ...a cubierta del cuello la tapa de la cubierta decorativa y la cubierta decorativa por el tubo Referirse al diagrama 3 Nota Se tiene que voltear la tapa de la cubierta decorativa para que el lado brillante dé al bastidor del motor Pasar el cable de seguridad y los cables por la bola que sirve para colgar y luego deslizar la bola que sirve para colgar sobre el tubo la parte de arriba del tubo debe te...

Page 18: ...el soporte de montaje puede causar lesiones graves o la muerte Sugerencia Solicitar ayuda de otra persona para mantener sujeta la escalera y para que le suba el ventilador cuando usted ya esté preparado en la escalera para colgarlo Encontrar un punto de acoplamiento seguro se recomienda la viga de madera en el techo y asegurar el cable de seguridad Utilizar tornillo para madera para trabajos pesad...

Page 19: ...es puede causar interferencia adversa en la radiocomunicación Sin embargo no hay ninguna garantía de que no habrá interferencia en una instalación en particular Si este equipo sí causa interferencia adversa en la recepción de radio o televisión que se puede determinar apagando y prendiendo el equipo se le urge al usuario a intentar rectificar la interferencia tomando una o más de las medidas que s...

Page 20: ...tornillos en la parte inferior del soporte de montaje y quitar el tornillo que está localizado más cerca del extremo abierto del soporte de montaje Aflojar parcialmente el otro tornillo Elevar la cubierta decorativa hasta el soporte de montaje Poner la parte redondeada del agujero con ranura en la cubierta decorativa encima del tornillo aflojado en el soporte de montaje y empujar hacia arriba Gira...

Page 21: ...nillo que se quitó anteriormente y apretar bien los 3 tornillos Instalar 3 bombillas de base candelabro de 60 vatios máx incluidas Importante Cuando necesite reemplazar las bombillas dejar que se enfríen las bombillas y la pantalla de vidrio antes de tocarlas Quitar el adorno con rosca la placa del adorno con rosca y la arandela con rosca de la varilla roscada en el conectador para el juego de luz...

Page 22: ... al diagrama 3 Alinear los agujeros en el control de pared con los postes que se encuentran adentro de la parte SUPERIOR de la cubierta del control remoto y apretar fijamente Colocar el control de pared dentro de la parte INFERIOR de la cubierta del control remoto alineando los postes en la parte superior de la cubierta del control remoto con los agujeros para los postes en la parte inferior Refer...

Page 23: ...s instrucciones de la sección 11 más arriba 12 Funcionamiento del control remoto Interruptor corredero ON OFF ENCIENDE y APAGA el control de pared el interruptor no funciona en el control de mano Botón HIGH pone el ventilador en velocidad ALTA Botón MED pone el ventilador en velocidad MEDIA Botón LOW pone el ventilador en velocidad BAJA Botón OFF APAGA el ventilador Botón L1 no se aplica para este...

Page 24: ...lador no funciona Soluciones 1 Inspeccionar el interruptor de pared del ventilador control de pared 2 Verificar la instalación eléctrica del control de pared uso opcional 3 Verificar la instalación eléctrica del ventilador 4 Es posible que no tuvo éxito el proceso de aprendizaje entre el ventilador el control remoto de mano y si se aplica el control de pared y que no se activó el código Desconecta...

Reviews: