background image

 

room or other dead-air spaces.  

Mounting Alarms 

1.

 

Twist off the mounting bracket from the alarm. 

2.

 

Put the bracket on the installation position and mark the 

screw holes on the ceiling or the wall.  

3.

 

Drill two mounting holes in the marked place by an 
electric drill (The diameter of the drill hole is 5mm) and 
insert two plastic anchor plugs by hammer.  

4.

 

Screw the mounting bracket to the ceiling or the wall 
(Refer to figure 3). 

5.

 

Attach the alarm to the mounting bracket and turn 
clockwise to lock the alarm  

 

WARNING: The installation instructions must be followed 

strictly in case of any injury.

 

                   

 

Figure 3

 

Test your Alarm 

Test the unit to ensure proper operation by pressing the  cover, 
the  alarm  will  sound  if  the  unit  are  working  well.  If  no  sounds, 
you can refer to “Trouble shooting” section for solution.  

 

CAUTION:  

1.

 

DO NOT test your alarm using an open flame. This may 
damage the smoke alarm, or ignite combustible materials 
and start a structural fire. 

2.

 

DO NOT stand close to the alarm when the alarm is 
sounding. Exposure at close range may be harmful to 
your earning, so step away when testing.  

3.

 

Weekly Test: test this smoke alarm once a week.  

 

LED Indicators 

1.

 

Normal status: Red LED Flashes once every 60 seconds. 

2.

 

Test status: Red LED flashes once every second.  

3.

 

Hush/Silence  mode:  Red  LED  flashes  once  every  8 
seconds.  

4.

 

Low  Battery  status:  Red  LED  flashes  once  every  60 
seconds and 1 beep every 60 seconds. 

Summary of Contents for SM11R

Page 1: ... Operation Current 30uA standby 70mA alarm Alarm Volume 85 dB A at 3 meters Alarm Sensitivity 0 09 0 17 dB m Low Battery 2 6 0 1 V Silence Time approx 10 minutes Frequency 433 92MHz or 868MHz Customized Working distance Up to 100m Outdoor open Interlinked devices Max 30pcs per group Source Master smoke alarm sound pattern BI 0 5s pause 0 5s BI 0 5s pause 0 5s BI 0 5s pause 1 5s with the red LED fl...

Page 2: ...he corners see the figure1 5 If the alarm is installed in the wall it should keep 100mm away from the ceiling 6 If the length of the room or the hall is beyond 30 foot you need to install several alarms there 7 When the wall or ceiling is slanting the alarm needs to be installed minimum 500mm away from the highest wall or ceiling point in the room see the figure 2 Figure 1 Figure 2 Locations to Av...

Page 3: ...3 Test your Alarm Test the unit to ensure proper operation by pressing the cover the alarm will sound if the unit are working well If no sounds you can refer to Trouble shooting section for solution CAUTION 1 DO NOT test your alarm using an open flame This may damage the smoke alarm or ignite combustible materials and start a structural fire 2 DO NOT stand close to the alarm when the alarm is soun...

Page 4: ...ase of the battery operated radio interlinked smoke alarms no wiring is required at all How to create the interlinked network Step 1 Press the test silence button on one of these smoke alarms 4 times and the green LED will rapidly flash continuously indicating it has entered the transmitting mode valid time 60 seconds Step 2 Press the test silence button on the other smoke alarms twice and the gre...

Page 5: ...r retailer Replaced Battery 1 The low battery signal can last for maximum 30 days please replace the batteries in time to keep it working properly 2 Battery required standard 1 5V AA alkaline batteries 3 Recommended battery brand DURACELL Energizer Golden Peak GP etc if use low quality battery it may cause the alarm work false or reduce service life 4 Correctly install the poles of the battery 5 T...

Page 6: ...scription of what is wrong with the unit Damage from neglect abuse or failure to adhere to any of the enclosed instructions will result in termination of the warranty and the unit will not be replaced or repaired This warranty shall not apply to the alarm if it has been damaged modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance The Manufactu...