SPECIFICATIONS

INTRODUCTION

Thank you for purchasing the CPS PROSET CR700 series unit. CPS is dedicated to give you the fastest and 

most reliable equipment to meet all your commercial refrigerant recovery requirements. In doing this CPS 

has integrated its latest technology and incorporated state of the art features while improving reliability and 

speed. The CR700 incorporates an Exclusive CPS Designed Patent Pending compressor that maximizes speed 

in both direct liquid and direct vapor recovery. The unit is equipped with a high airflow and high efficiency 

condensing system to maximize vapor recovery speed. The CR700 also incorporates an automatic Low 

Pressure shut off switch.

The CR700 is designed for servicing commercial and residential refrigeration systems. Simply follow the 

quick start guide and turn it on. Once the recovery is complete, simply turn the center valve to the SELF-

CLEARING position.  Now the unit is ready for the next type of refrigerant.

The PROSET CR700 series utilizes a 1 hp (0.85kW) patent pending oil-less compressor, non-restrictive 

piston manifold valves, and high capacity condensing system.

The following are additional features:

• “On the Run” SELF-CLEARING valve. No need to turn off the unit when switching from recovery to

self-clearing.

• On board SUCTION and DISCHARGE gauges.

• 0 to 55 bar (800-psig) discharge gauge to handle R-410A.

• Small physical size.

• Automatic Low Pressure cutout switch.

• Integrated easy to use carrying handle and Safety bar.

• 550 psig High Pressure cutout switch

• Easy and secure filter accesses.  No dangling filters to be damaged.

Models

Compressor Type

Dimensions

Weight

Operating Temperature Range

Power Source

Power Consumption

Suction Pressure Gauge

Discharge Pressure Gauge

Filtration

Shut-Off Valves

Construction

Overload Protection

High Pressure Shut-Off

Refrigerants

Flow Rate

(at 60hz, reduce 15% for 50hz)

Direct Vapor

Direct Liquid

Push-Pull Liquid

-30” hg to 350 psig

-1 to 34.5 bar           -.1 to 3.5 MPa       -30” hg to 350 psig

-76 cm hg to 35 kg/cm

-100 kPa to 3450 kPa

-76 cm hg to 35 kg/cm

0 to 800 psig

0 to 55 bar

0 to 5.5 MPa

0 to 800 psig

0 to 55 kg/cm

0 to 5500 kPa

0 to 55 kg/cm

Cleanable 100-mesh screen integrated into Suction Port

Both Suction and Discharge piston manifold valves

Heavy gauge aluminum chassis with High Density Polyethylene Case

15 amp

8 amp

15 amp

8 amp

38 bar (550 psig)

R-12, R-134a, R-401C, R-406A, R-500, R-401A

R-409A, R-401B, R-412A, R-411A, R-407D, R-22

R-411B, R-502, R-407C, R-402B, R408A, R-509

R-407A, R-404A, R-402A, R-507, R-407B, R-410A

Up to 43 kg/hr       Up to 1.6 lb/min

Up to 271 kg/hr      Up to 10 lb/min

Up to 542 kg/hr      Up to 20 lb/min

850 W

115 V 50/60Hz 1 Ph  220-240 V 50/60 Hz 1 Ph  100 V 50/60 Hz 1 Ph  230 V 50/60 Hz 1 Ph

0°C (32°F) to 49°C (120°)

15.3 kg  (34 lbs.)

20cm (8”) wide x 37cm (14.5”) long x 30.5cm (12”) high

1 HP Oil-less Reciprocating Compressor

CR700/CR700JUK*

CR700E

CR700J

CR700S

* uses same gauges as CR700E

Summary of Contents for PRO-SET CR700 Series

Page 1: ...EL ONLY 1 HP Commercial Refrigerant Recovery System OPERATION MANUAL TABLE OF CONTENTS Specifications Introduction General Safety Instructions Direct Liquid or Vapor Recovery Operation Liquid Push Pull Operation Routine Maintenance 2 2 3 3 4 4 5 ENGLISH 1 5 ...

Page 2: ...harge gauge to handle R 410A Small physical size Automatic Low Pressure cutout switch Integrated easy to use carrying handle and Safety bar 550 psig High Pressure cutout switch Easy and secure filter accesses No dangling filters to be damaged Models Compressor Type Dimensions Weight Operating Temperature Range Power Source Power Consumption Suction Pressure Gauge Discharge Pressure Gauge Filtratio...

Page 3: ...athing high concentration levels may cause heart arrhythmia loss of consciousness or even cause suffocation DANGER ELECTRICAL SHOCK HAZARD Always disconnect power source when servicing this equipment DANGER EXPLOSION RISK Do not recovery flammable refrigerants CAUTION all hoses may contain liquid refrigerant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear...

Page 4: ...CLEARING position The CR700 will resume operation automatically The CR700 is now clearing out the condensor The CR700 will automatically shut off when a 10 hg vacuum is achieved Note If the LP override switch is set to ON position the unit will run continuously RECOVERY AND SELF CLEARING ARE COMPLETE LIQUID PUSH PULL OPERATION 1 Connect the unit as shown in Diagram 2 Note The recovery tank must be...

Page 5: ...ure 1 Once loose remove the suction port filter cartridge as shown in Figure 2 Either clean the current cartridge or replace with new cartridge Inspect O ring Re lubricate with compressor oil or equivalent Place filter cartridge back into suction port fitting Hand tighten this assembly back onto the CR700 Use a 5 8 socket or boxed end wrench to tighten 1 8 of a turn Do not over tighten damage to t...

Reviews: