background image

Sensor:

State of the art E_MOS

®

 technology.

Gases:

Detects refrigerants including those with 

hydrocarbon components (CFC, CH2F2, 

HCFC,  HFC,  HFO,  NH3,  HC.  Hydrogen 

trace gas in 95% N2, 5% H2 mixture A2L 

refrigerants). 

CAUTION: This leak detector is not 

intrinsically safe. Use in well ventilated areas

.

Sensitivity:

Better than a 0.1 oz / year (3 g / annually) for 

all common refrigerants, including R-410a, 

R-404a and R-407a.

Audible Alarms:

A bar-graph LED display shows the relative 

leak size in each of 7 possible ranges. Each 

range is indicated by a numbered LED. Each 

range is automatically selected by the instru-

ment starting with highest sensitivity and 

automatically switching to lower sensitivities 

as the leak source is approached.

Operating 

Temperature:

-18 to 60˚C (0 to 140˚F)

Power:

Three size "C" alkaline batteries (NEDA/

ANSI 14A).

Battery Life:

50 hours minimum at 77˚F (25˚C). Battery 

life depends on cell chemistry and ambient 

conditions. Alkaline batteries provide longest 

life. Cold ambient conditions decrease bat-

tery life. The 

Leak-Seeker 

®

 

II

 turns itself off 

after 10 minutes of inactivity—

START

 button 

not pressed—to further prolong battery life.

Dimensions:

Instrument  (L  x  W  x  H):  10"  x  2.3"  x  2" 

254mm x 59mm x 51mm

Probe:

 

15" (380mm) long, .25" (6.4mm)diameter.

Weight:

1 lb 2 oz (500 g)

Certifications:

Complies with European Standard

EN14624:2012

Leak-Seeker 

®

 

II

 Specifications

3

GENERAL INFORMATION

Summary of Contents for Leak-Seeker II

Page 1: ...Leak Seeker II Refrigerant Leak Detector CE US Patent8 555 701 OPERATION MANUAL Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ...nsor Replacement Diagram 8 Warranty 9 2 Introduction One button operation for reset changing of audible alarm range and power off Six sensitivity ranges automatically selected by instrument Flexible metal probe 15 380mm long 25 6 4mm diameter High output alarm speaker Bar graph indicator displays relative leak size Sensor inside protective metal housing with filter GENERAL INFORMATION ...

Page 3: ... instru ment starting with highest sensitivity and automatically switching to lower sensitivities as the leak source is approached Operating Temperature 18 to 60 C 0 to 140 F Power Three size C alkaline batteries NEDA ANSI 14A Battery Life 50 hours minimum at 77 F 25 C Battery life depends on cell chemistry and ambient conditions Alkaline batteries provide longest life Cold ambient conditions decr...

Page 4: ...hile searching for leaks Features Microprocessor controlled sensor electronics utilizing a multi channel signal detection method improves sensitivity while reducing false alarms New E_MOS sensor technology incorporates a proprietary pulse modulation design to increase both battery and sensor life Software managed sensor rejuvenation mode automatically initiated at each startup ensures the highest ...

Page 5: ...ent OFF At any time during operation press and hold down the yellow START button until the LED display turns OFF This indicates that the unit has been shut down Low battery indicator When the batteries reach approximately 10 of capacity the rightmost bar graph LED will stay lit above the LO BAT legend Windy conditions Locating leaks under windy conditions may severely impede the leak searching pro...

Page 6: ...eas around attachment points and hold down on lines and components 2 Always follow the refrigerant system around in a continuous path so that no areas of potential leaks are missed If a leak is found always continue to test the remainder of the system 3 At each area checked the probe should be moved around the location at a rate no more than 1 2 in sec 25 to 50mm sec and no more than 2 5mm from th...

Page 7: ......

Page 8: ......

Page 9: ...antee does not apply to equipment that has been altered misused or returned solely in need of field service maintenance This repair policy does not include equipment that is determined to be beyond economical repair All products being returned for warranty repair must be accompanied by an original bill of sale and customer contact information 9 WARRANTY Test Equipment Depot 800 517 8431 99 Washing...

Reviews: