UNIT DESCRIPTION
Re.:
Description
Note
1
High Pressure Gauge
For the inspection and diagnosis of the A/C system
2
Tank Pressure Gauge
To check the pressure inside the gas storage reservoir.
3
Low Pressure Gauge
For the inspection and diagnosis of the A/C system and for
the control of the vacuum.
4
Thermal printer position
Prints a report on the carried-out cycles
5
LCD Display
Visualizes the operations of the unit
6
Buttons
Control buttons
7
Button
“Down”
To browse the menus or decrease the values of the various
parameters
8
Button
“UP”
To browse the menus or increase the values of the various
parameters
9
Button
“EXIT”
Interrupts any whatsoever operation, to exit and return to
the previous menu
10
Button
“ENTER”
To select and confirm the different functions, or to enter the
following menu
11
Hoses storage
To place instruction manual or hoses when not in use
12
New/old oil bottles
Store the new oil and the drained oil
13
Main switch
Shows the machine data (serial no., year of construction)
14
Identification plate
To connect the charging hoses LP / HP
15
Main LP (blue) and HP(red) couplings To power the machine (220-240V 50 Hz)
16
Serial port
To update the databank of the unit
17
Ventilation fan
Internal ventilation fan (
CSA1234 model only)
18
Safety valves inspection door
To inspect the safety and the NCG release valve
19
Vacuum pump ventilation grid
To ventilate and inspection the vacuum pump
20
New oil bottle
New oil storage / new oil storage for hybrid vehicles
21
Old oil bottle
Drained oil storage
22
Dye bottle
OR
hybrid. Oil
bottle position
Dye storage
OR
hybrid oil storage
23
Non-condensable gas release valve Automatically releases non-condensable gases
24
Max pressure valve
Automatically releases pressure if max pressure is
reached. Allows to manually release NCG gases if present