GENERAL INFO
Warning icons used in the present manual
Safety devices
A) Pressure relief valve on internal gas tank: releases pressure if 18 Bar are exceeded in the gas tank
B) Safety fan: ventilates the unit continuously when in use. The software displays a warning message in
case of failure of this fan.
This device applies to R1234YF models only: CSA1234
Please be aware that whatever damages due to a wrong or improper use of the recharging station will
not be covered by our warranty. Consumables like packing and seals for hoses and quick couplings,
fuses and damages occurred during transport are not part of the warranty.
Caution!
Connected to
230V socket
50Hz
Wear gloves
when handling
refrigerants
Wear goggles
when handling
refrigerants
Protect against
moisture,
humidity
Read
instruction
manual
carefully
•
CAUTION-
Use only CPS certified hose assemblies on this unit. The hose assemblies are made to
proper length, contain shut offs where required and have direct effect on the proper operation of this
equipment.
•
Do not smoke
whilst using the recharging unit.
•
During the operations, l
ocate the unit on a flat
and leveled surface.
•
Do not use
the unit i
n very humid and wet environments
or in the rain.
•
During maintenance operations
disconnect the unit from the electrical power
.
•
Avoid removing the connecting hoses
if not necessary; in case always make sure there is a
vacuum in the hoses before using again.
•
Follow
the information and the instructions
of the refrigerant manufacturer.
•
Observe
any instructions on servicing vehicle A/C systems which apply at your company.
•
Only use original spare parts
and accessories.
•
Use
authorised additives or consumables only (ask for advice from an authorised reseller).
•
Before starting
the machine, first
check each time
whether the charging hoses and the quick
couplers are undamaged and are not leaking.
•
Recover
refrigerant from the hoses before releasing the quick connections.
•
Make certain that all safety devices are functioning properly before operating the equipment.
•
Do not
leave the unit unattended when switched on; Use the main switch to switch off the unit after its
use.
•
Never release
the refrigerating gas
into the environment
.
•
Maintenance operations must be carried out by
specialized and authorised personnel
.
•
Do not
violate for any reason at all
the safety devices
the unit is equipped with, like the high-
pressure valve of the internal reservoir.
•
Use
with refrigerant indicated on the data plate only (
HFO-1234YF or R134a
).
Do not
make
modifications to the service unit.