Electrical Connection
19 / 32
4.2.2
Indicator description
Icon
indicator name
Color Function
PWR Power indicator
Green Flashes after power-on, flashing interval is
1s, and flashing time is 100ms.
PLC
Communication
indicator
Red
Flashes
after
PLC
networking
is
completed, the interval is 1s, and the
flashing mode is alternately on and off.
TX
RS485
port
sending indicator
Green Flashes when sending data.
RX
RS485
port
receiving indicator
Red
Flashes when data is received.
Table 4-4 Indicator description
Recommended tools and torque
Name
Cable specifications Tool
Torques
AC Input
#14AWG
Screwdriver
2.8N·m
Antenna
Comes with device
0.5N·m ~ 0.6 N·m
COM1/COM2
shielded cables
0.5N·m ~ 0.6 N·m
Grounding
#6AWG
2±0.2 N·m
Table 4-5 Recommended tools
Cable connection
WARNING!
This device is designed as a communication product, only qualified
personnel who are granted relevant access can implement the installation,
wiring, operation and maintenance work.
Please open the front door of the main enclosure according to the following steps
described below.
1.
Insert your keys into the lock hole (3) and turn it to the ON position.
2.
Pull the lock handle (1) outward till separating it from the lock bar (2).