Heat and Acoustic 

 

 
Heat Dissipation 

1100 watts max. 

 

 

   

   

 

 

 

Acoustic Noise 

65 dBA (as measured at 3 ft.) 

 

MONITORS AND CONTROLS 

 

Control Functions 

Main Power On/Off   

 

 

   

TX (Transmit) Select 

 

 

   

Transmit/Standby (Beam on/off) 

 

   

RF Drive Adjust (manual standard)  

   

Local/Remote/Computer (CIF) Select 

 

 

Indicator 

Test    

  

Fault 

Reset 

 
Monitoring 

      

 

RF 

Output 

Power 

   

 

 

      

  

 

Attenuator 

Setting 

   

   

 

 

 

 

 

  

  RF Output Sample Port (-40 dBm nominal, 

   

 

 

 

 

 

              Type N) 

 

 

 

 

   

 

 

 

 

 

 

  RF Reflected Power (W) 

 

 

   

 

 

 

 

 

        

  Helix Current (mA)   

 

 

   

 

 

 

 

 

 

  Helix Voltage (kV) 

 
Control/ Status Display 

 

 

Power On 

   

 

   

 

 

Heater Time Delay (HTD)   

   

 

 

TX (Transmit) Select   

 

  

 

 

Standby 

   

 

   

 

 

Transmit (Beam on)    

 

  

 

 

Local/Remote/CIF    

 

  

 

 

Meter 

Select 

 
Fault/Alarm Display 

 

 

Recycled Fault 

 

 

 

 

 

 

  

Fault 

  

 

 

  

 

 

Low 

RF 

 

 

 

 

   

 

 

High Reflected RF   

 

 

   

 

 

Interlocks Open (power supply temp. or am-

  

 

 

plifier 

cover) 

 

 

 

  

 

 

Helix 

Over-current  

 

 

  

 

 

Helix 

Voltage 

 

 

 

   

 

 

Power Supply Arc   

 

 

   

 

 

DC Buss Fault 

 

 

 

  

 

 

TWT 

Over-temperature 

 

 

Ku-Band CMPA  04/08 

 

TD-67  Page 11 

Summary of Contents for VZU-6994

Page 1: ...l Safety Standard EN 60215 Electromagnetic Compatibility 89 336 EEC and Harmonic Standard EN 61000 3 2 to satisfy worldwide requirements Easy to Maintain Modular design and built in fault diagnostic c...

Page 2: ...rier output 22 dBc max at 7 dB OBO 4 dB w lin for 14 7 15 2 GHz config Group Delay 0 01 ns MHz linear max in any 80 MHz band 0 001 ns MHz2 parabolic max 0 5 ns pk pk ripple max Environmental Operating...

Page 3: ...g the unit to meet the total harmonic distortion requirement of EN61000 3 2 and providing for universal voltage input 100 240 VAC It is also designed to meet EN60215 safety and 2004 108 EC electromagn...

Page 4: ...e set during installation up down buttons that permit setting high and low alarm trip points such as Low RF and a set of detail fault LEDs to help troubleshoot during operation Principal functions are...

Page 5: ...PPM focused helix design It is designed especially for compact lightweight applications involving satellite uplink service The output waveguide assembly interfaces to the TWT and protects the tube fr...

Page 6: ...ly the AC input power is required for operation The travelling wave tube derives its operation from four DC power supplies a filament heater low voltage supply a helix high voltage supply and two coll...

Page 7: ...current sense resistors for critical TWT voltages The incoming 200 volt 21 kHz signal is applied to the primary of a multi section high voltage transformer which provides all of the high voltage level...

Page 8: ...e longest HTD is three minutes If a fault occurs during TRANSMIT the FAULT LED will light and the unit will switch from TRANSMIT to FAULT Two scenarios are possible The first scenario occurs when a fa...

Page 9: ...by 5 25 high and 24 deep plus connectors fan and air duct adapters The unit is cooled via a forced air cooling system consisting of two axial fans an air filter and an exhaust duct Allowances are mad...

Page 10: ...VZU 6994 AB 1750 MHz VZU 6994 AP 500 MHz Gain at rated power 73 dB min 88 dB max small signal 78 dB min 90 dB max RF Level Adjust Range 0 to 20 dB Output Power Setability 0 2 dB Gain Stability at cons...

Page 11: ...Harmonic Output 60 dBc at rated power second and third harmonics Noise and Spurious at rated gain VZU 6994 AC AD AP 150 dBW 4 kHz 10 9 to 12 7 GHz VZU 6994 AB 130 dBW 4 kHz 10 9 to 11 7 GHz VZU 6994...

Page 12: ...derating of 2 C 1 000 ft non operating 40 000 ft Shock and Vibration Designed for normal transportation environ ment per Section 514 4 MIL STD 810E De signed to withstand 20G at 11 ms 1 2 sine pulse...

Page 13: ...RF Output Power Attenuator Setting RF Output Sample Port 40 dBm nominal Type N RF Reflected Power W Helix Current mA Helix Voltage kV Control Status Display Power On Heater Time Delay HTD TX Transmit...

Page 14: ...ES Options Compatibility Integral linearizer External receive band reject filter increases loss by a minimum of 75 dB up to 12 75 GHz for standard band and by a minimum of 50 dB up to 11 7 GHz for ext...

Page 15: ...tion local or remote as selected by the operator For servicing the logic assembly can be removed from the front panel without disturbing the RF connections Options are available for the addition of an...

Page 16: ...e with the Switching System and Phase Combiner SUPPORT SERVICES Documentation CPI Satcom Division provides a standard commercial documentation package for all products The standard package for satelli...

Page 17: ...f CPI includes a staff of experienced professional service technicians to assist users in maintaining full performance from their CPI power amplifiers A telephone hot line permits access to one of the...

Page 18: ...gure 1 CMPA Outline Drawing ref 01018602 rev A dtd 02 06 Note Before using this drawing for system design please check with CPI to ensure that it is the latest revision Ku Band CMPA 04 08 TD 67 Page 1...

Page 19: ...OLATOR TWT I NT EGRATED RF OUTPUT ASSEMBLY RFOUTPUT WR 75 G ROO VED 40 DB 59 DB 50 DB RFOUTPUT SAMPLE PORT TYPE N FEMALE RF OUTPUT POWER RF REFLECTED POWER Contains integral PIN Diode Attenuator Figur...

Page 20: ...rol Switching I F Serial Remote Control For use with CPI Remote Panel Computer I F User Interlocks Control Display Micro controller RF Metering Faults Control DC Power Monitor Control HV Module Helix...

Page 21: ...Ku Band CMPA 04 08 TD 67 Page 19 Figure 4 CMPA Front Panel Ku Band CMPA 04 08 TD 67 Page 19...

Page 22: ...MFG REL CL A A02717 5 16 03 CLS GE B INC E C O A03689 2 13 06 ON FJ C INC E C O A03862 6 12 06 ON FJ D INC E C O A04491 3 3 08 FJ FAMILY CONFIGURATION AND OPTIONS 400w COMPACT MPA Ku BAND CMPA MODEL...

Page 23: ...Code Option Description Option Part Number 1 Prime Power 0 Single Phase 110 240 VAC Standard None 2 Front Panel Assembly 0 Standard 01018626 00 S Special Front Panel Assembly 01019455 XX 3 Attenuator...

Page 24: ...h or written permission from the Corporation Space Code Option Description Option Part Number 8 9 01 Short Exhaust Duct See accessories 01020747 00 02 Receive Filter External See accessories 01020654...

Page 25: ......