Troubleshooting

These are some common, easy-to-solve issues that may pop up during installation:

Compliance

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (a) This device may not cause harmful interference, and (b) this device must accept any interference 

received, including interference that may cause undesired operation.

Except as permitted under the relevant local legislation, no part of this publication may be copied, transmitted, transcribed, or distributed in any form or by any means, or stored in a database or retrieval system, 

or translated in any language (natural or computer), without the prior written permission of CPI.

CPI reserves the right to change the product or the product specifications at any time. While every effort has been made to ensure that the information in this publication is accurate, CPI disclaims any liability for 

any direct or indirect losses (howsoever caused) arising out of use or reliance on this information. This document does not necessarily imply product availability. Note: Your product may differ slightly from some 

of the illustrations in this document.

If this happens

Try

The unit will not power 
up

Check Harnesses: Cables may be 
loose, not properly connected or pins 
may be bent

Check Source Voltage: Ensure that 
power is being supplied to the bill 
validator.

The unit has power, but 
will not accept a bill

Ensure the unit has been enabled, then 
check: 

 

   • Vending Machine Controller

 

   • Coin manager and coin levels

 

   • Inventory levels

 

   • The door is locked properly

Cleaning

The Talos bill validator will not need to be cleaned as often as magnetic sensing bill acceptors. If cleaning is required, use a soft cloth moistened with a mild, non-
abrasive detergent.

Talos Install Guide_Web_5.24.19.indd   4

5/24/2019   9:57:14 AM

Summary of Contents for Talos T700

Page 1: ...arness Apply gentle pressure to connect the pins will bend if forced 4 Turn on power to the vending machine 5 Check the LEDs on the front of Talos The LEDs should be flashing In some cases the machine door must be closed first 6 Once the LEDs are flashing test the validator with a 1 bill a Insert 1 and confirm that it stacks and credit is given b Repeat this process for any other enabled bills 7 W...

Page 2: ... Face up or down in either direction 2 Bills Enabled On or off to enable or disable a bill 3 Recycled Bill Can be left blank but is required for the recycler 4 Accept Inhibit Requires a Recycler 5 Acceptance Mode Mode 0 Factory default No acceptance modes active Mode 1 If fraud is detected the validator enters an out of service time out the stacker plate extends into the bill magazine and the beze...

Page 3: ...hold a bill in the bill path until the bezel lights flash Count the flashes and refer to the chart below Flashes Problem Solution None No power Restore power to validator or machine 1 or 4 Bill path blocked Check for jams Remove bill magazine and lower housing assembly and inspect 2 Another vending component Ensure the unit has been enabled then check Vending Machine Controller Coin manager and co...

Page 4: ...ions at any time While every effort has been made to ensure that the information in this publication is accurate CPI disclaims any liability for any direct or indirect losses howsoever caused arising out of use or reliance on this information This document does not necessarily imply product availability Note Your product may differ slightly from some of the illustrations in this document If this h...

Reviews: