background image

Configuration Coupons - Continued

Bezel LED Error Flash Codes

I

nsert the configuration coupon and verify the settings were accepted by counting the bezel flashes

 

Flashes

Meaning

10

Configuration coupon accepted and unit 
successfully programmed.

1 - 5

Coupon rejected. Number of flashes corresponds 
to the coupon section that was improperly filled 
out. Try again. 

7

Coupon not read. Confirm the coupon is 

 

correct and try again.

When the unit is ready and enabled, the bezel LEDs will flash continuously. If the bezel LEDs are off, the unit has an error. To determine the error, partially insert 
and hold a bill in the bill path until the bezel lights flash. Count the flashes and refer to the chart below. 

Flashes

Problem

Solution

None

No power

Restore power to validator or machine

1 or 4

Bill path 
blocked

Check for jams. Remove bill 
magazine and lower housing 
assembly and inspect

2

Another 

vending 

component

Ensure the unit has been enabled, 
then check: 

 

   • Vending Machine Controller

 

   • Coin manager and coin levels

 

   • Inventory levels

 

   • The door is locked properly

3

Lower 
housing 
assembly 

Check that the lower housing 
assembly is seated. Ensure bill path 
is clean; see Cleaning section

5

Bill magazine 

removed

Reattach bill magazine

Continuous  
fast

Stacker full

Empty the bill magazine

Continuous 
slow

Unit is 

defective

Replace the unit

Talos Install Guide_Web_5.24.19.indd   3

5/24/2019   9:57:14 AM

Summary of Contents for Talos T700

Page 1: ...arness Apply gentle pressure to connect the pins will bend if forced 4 Turn on power to the vending machine 5 Check the LEDs on the front of Talos The LEDs should be flashing In some cases the machine door must be closed first 6 Once the LEDs are flashing test the validator with a 1 bill a Insert 1 and confirm that it stacks and credit is given b Repeat this process for any other enabled bills 7 W...

Page 2: ... Face up or down in either direction 2 Bills Enabled On or off to enable or disable a bill 3 Recycled Bill Can be left blank but is required for the recycler 4 Accept Inhibit Requires a Recycler 5 Acceptance Mode Mode 0 Factory default No acceptance modes active Mode 1 If fraud is detected the validator enters an out of service time out the stacker plate extends into the bill magazine and the beze...

Page 3: ...hold a bill in the bill path until the bezel lights flash Count the flashes and refer to the chart below Flashes Problem Solution None No power Restore power to validator or machine 1 or 4 Bill path blocked Check for jams Remove bill magazine and lower housing assembly and inspect 2 Another vending component Ensure the unit has been enabled then check Vending Machine Controller Coin manager and co...

Page 4: ...ions at any time While every effort has been made to ensure that the information in this publication is accurate CPI disclaims any liability for any direct or indirect losses howsoever caused arising out of use or reliance on this information This document does not necessarily imply product availability Note Your product may differ slightly from some of the illustrations in this document If this h...