background image

 

 

 [Document Title Name Goes Here] 

 

 

 

R900 Installation Guide 

 

The R900 bill validator is designed to fit into the standard bill acceptor opening 
in most vending machines and can be mounted on existing studs or a mounting 
bracket 

 

 

Features 

-

 

Four way bill acceptance 

-

 

Multi-width bill handling mechanism 

-

 

Lockable security cashbox (lockable) available 

 

Interface 

-

 

The R900 bill validator operates via MDB interface 

-

 

PC base; RS232C interface CCNET protocol is also available 

 

Operating Voltage 

-

 

34VDC/24VDC for MDB interface 

-

 

12VDC for CCNET interface (RS232C base) 

 
 
 
 

INSTALLATION 

 

Before installation, remove the R900 bill validator from the packaging and inspect for any physical damage. If damaged, contact 
technical support 

 

1.

 

Turn off power from the vending machine. 

2.

 

Remove the bill magazine. Press forward on the yellow latch on the bill magazine and pull to remove.  

3.

 

Mount the R900 bill validator on the mounting studs, through the opening in the front of the vendor and secure using the included 
hardware. 

4.

 

Connect the R900 bill validator to the appropriate interface harness. Apply gentle pressure to connect; the pins will bend if forced. 

5.

 

Turn on power to the vending machine. 

6.

 

Check the arrow LED on the front of R900. The LED should be flashing. In some cases, the machine door must be closed first. 

7.

 

Once the LED is flashing, test the validator with a bill. 

a.

 

Insert a bill and confirm that it stacks and credit is given 

b.

 

Repeat this process for any other enabled bills. 

8.

 

When your test is completed, remove the test bills from the bill magazine. 

 
 
 
 
The installation is now complete. Refer to the other sections of this guide to configure the device, if necessary. 

 

 

Summary of Contents for R900

Page 1: ...from the vending machine 2 Remove the bill magazine Press forward on the yellow latch on the bill magazine and pull to remove 3 Mount the R900 bill validator on the mounting studs through the opening in the front of the vendor and secure using the included hardware 4 Connect the R900 bill validator to the appropriate interface harness Apply gentle pressure to connect the pins will bend if forced 5...

Page 2: ... 3 4 ON B1 B2 B3 B4 1 2 3 4 ON No ON A1 Description Bill 1 OFF Accepted Inhibited No A2 A3 A4 Bill 2 Bill 3 Bill 4 Accepted Inhibited Accepted Inhibited Accepted Inhibited ON B1 Description Bill 5 OFF Accepted Inhibited B2 B3 B4 Bill 6 Com Speed Security Accepted Inhibited 9600bps 19200bps Standard High A1 A2 A3 A4 1 2 3 4 ON B1 B2 B3 B4 1 2 3 4 ON customizing Bill acceptance The R900 ships from t...

Page 3: ... Active High Security Mode Upon power on when the initial cycle is completed the lamp operates one flash cycle in Green 0 3s 5 times to indicate in high security mode Flashing in Green Every 0 5s In Cleaning Mode Ready to be inserted cleaning sheet to clean up the bill path OFF No Power Communication Error Inhibited All Bills Bill is in Inlet Sensor Busy in validation Abnormal State Turn on Power ...

Page 4: ...ion Error Check Connector Check Machine Status Flash 1 OFF Active High Security Mode Check the DIP SW setting Flash 2 OFF Dirty Sensors Acceptance Rate 80 Need to Clean Sensors Flash 3 OFF Abnormal Error Refer to OP manual Contact ASC OFF Flash 1 Cashbox Out of Position Cashbox is Opened Close Cashbox OFF Flash 2 Cashbox Full Check Cashbox Collect Bills OFF Flash 3 Sensor Errors Check the Sensor S...

Page 5: ...sors Clean the sensors referring to the REGULAR MAINTENANCE Specific bills are not accepted Is the DIP SW setting correctly Set DIP SW to be enabled referring to the ENABLING BILLS Is there any dirt on the validation sensors Clean the sensors referring to the REGULAR MAINTENANCE Poor Acceptance Is the security mode set as High Set DIP SW to be standard referring to the ENABLING BILLS Is there any ...

Page 6: ...cleaning is recommended to maintain high acceptance rates We recommend a regular cleaning maintenance once every 3 6 months If cleaning is required use cleaning sheet under the cleaning mode or use a soft damp cloth Do not use abrasive cleaning products Cleaning Mode Use proper cleaning sheet CPI supported Contact local ASC To enter the Cleaning Mode press the push switch twice The bezel lam start...

Page 7: ...CONTACT U S Crane Payment Innovations CPI Corporate Headquarters 3222 Phoenixville Pike Suite 200 Malvern PA 19355 CranePI com ...

Reviews: