Congratulations on your purchase of Cooking Performance Group commercial cooking equipment! At Cooking
Performance Group, we take pride in the design, innovation, and quality of our products. When used as
intended and with proper care and maintenance, you will experience years of reliable operation from your
Cooking Performance Group equipment. To ensure optimal performance, we have outlined the following
instructions and guidelines in this manual carefully for your review.
SAFETY PRECAUTIONS
CAUTION:
Potential hazard or unsafe practice could result in minor or moderate injury or product or property
damage.
NOTICE:
• Local codes regarding installation vary greatly from one area to another. The National Fire Protection
Association, Inc., states in its NFPA96 latest edition that local codes are “Authority Having Jurisdiction” when it
comes to requirement for installation of equipment. Therefore, installation should comply with all local codes.
• This product is intended for commercial use only. Not for residential use.
WARNING:
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• Improper installation, adjustment, alteration, service or maintenance could lead to property damage, injury or
death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing
CPG equipment. This manual must be retained for future reference.
• Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user
smells gas. Safety information can be obtained from your local gas supplier.
• An authorized service agency should handle all maintenance and repair. Prior to conducting any maintenance
or repair work contact your authorized service representative.
GAS PRESSURE:
The appliance and its individual shutoff valve (to be supplied by user) must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 PSI (3.45 kPa). The
appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than
1/2 PSI (3.45 kPa).
SERIAL PLATE
NOTE:
The serial plate is located
on the side of the unit.
Made in China
Item # 351CLCPG15
Model # CBL15
LAVA BRIQUETTE CHARBROILER 15"
Total BTU: 40,000
Gas Type: Natural gas
Manifold Pressure: 6" WC
Orifice Size: # 36
CBL15-NG(CPG)
04.03.1317582
Arial 6.5pt
Arial 6.5pt
Arial 6.5pt
Arial Bold 9pt
Arial Bold 6.5pt
1
2
3
4
编号
内容
名称
公司LOGO
认证LOGO
认证LOGO
大小:37.5*29毫米
大小:10*13.7毫米
大小:16.5*16毫米
文件规格明细:
Black
Black
COLOR:
铭牌标贴(自制)
修改序列号格式
修改铭牌材质
修改铭牌尺寸
C
1
2
3
4
变量, 11:年份 01:月份 000001 序列号
序 列 号
CLEARANCE REQUIREMENTS:
Combustible Sides: 6”
Combustible Back: 6”
Serial # 1101000001
Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD-2016
Conforms to NSF / ANSI STD. 4
Lancaster, Pennsylvania
135
135
技术要求:须符合ROHS要求
WARNING
• Equipment must be installed by a certified technician. Improper installation, adjustment,
alteration, service, or maintenance of this equipment may cause property damage or
personal injury and voids warranty.
• Carefully read and follow the installation and owner's manual prior to equipment installation or use.
• Properly attach the legs provided before appliance is permanently installed and before use.
• Use only on non-combustible countertops and away from any combustible material.
• Equipment must be installed under proper ventilation as required per local code.
• Conversion to other gas types must be performed by a certified technician only.
This appliance is equipped with a gas pressure regulator. The regulator is factory set at 6” WC for nat, or 10” WC for
propane. For your safety, call an authorized technician for any gas conversion changes. Do not attempt to make conversion
changes yourself.
Any changes made by a non-authorized technician voids warranty. This appliance has been regulated for:
Natural gas 6” WC factory setting
Propane 10” WC factory setting
Note: An authorized technician may convert this unit from one gas type to the other.
Prior to conversion, the unit must be adjusted to the correct gas pressure.
Lighting Instructions
1. Turn all knobs until they are straight up-and-down in the vertical position.
2. Turn on the main valve, and wait 10 seconds to clear the gas for first use.
3. Hold an ignition source (match) at the pilot. When the flame is established, remove the ignition source.
4. Turn the burner knobs to "HIGH". If the burner does not ignite, promptly increase gas flow by continuing to open the pilot valve.
Do this carefully. If the pilot flame appears larger than necessary, turn it down, and reset the burner ignition.
The pilot flame should be just large enough to guarantee reliable burner ignition when the knobs are in the vertical position.
Note: To turn off the pilot burner, the gas supply must first be cut off.
铝板
A6061 T=0.8
阳极发黑
Made in China
Item # 351S60G24N
Model # S60-G24-N
60” GAS RANGE
Total BTU: 30,000
Gas Type: Natural Gas
Manifold Pressure: 4” WC
Orifice Size: # 54
CLEARANCE REQUIREMENTS:
Combustible Sides: 6”
Combustible Back: 6”
Serial # 1010101010101
Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD-2016
Conforms to NSF / ANSI STD. 4
Intertek
Summary of Contents for 351S24 Series
Page 4: ...USER MANUAL 4 www CookingPerformanceGroup com 351S36 L N 351S24 L N...
Page 5: ...USER MANUAL 5 www CookingPerformanceGroup com 351S36G24 L N 351S60 L N...
Page 6: ...USER MANUAL 6 www CookingPerformanceGroup com 351S60G24 L N 351S60GS24 L N...
Page 14: ...USER MANUAL 14 www CookingPerformanceGroup com 18 a b 13 a b 16 RANGE MAIN BODY...
Page 20: ...USER MANUAL 20 www CookingPerformanceGroup com 18 a b 13 a b RANGE MAIN BODY...
Page 26: ...USER MANUAL 26 www CookingPerformanceGroup com 18 a b 13 a b RANGE MAIN BODY...
Page 32: ...USER MANUAL 32 www CookingPerformanceGroup com PARTS DIAGRAM 351S36G24 L N...