background image

USER MANUAL

www.CookingPerformanceGroup.com

 Made in China
 Item # 351CLCPG15
 Model # CBL15
 LAVA BRIQUETTE CHARBROILER 15"
 Total BTU: 40,000
 Gas Type: Natural gas
 Manifold Pressure: 6" WC 
 Orifice Size: # 36

CBL15-NG(CPG)

04.03.1317582

Arial  6.5pt

Arial  6.5pt

Arial  6.5pt

Arial Bold  9pt

Arial Bold  6.5pt

1

2

3

4

编号

内容

名称

公司LOGO

认证LOGO

认证LOGO

大小:37.5*29毫米

大小:10*13.7毫米

大小:16.5*16毫米

文件规格明细:

Black

 

Black

 

COLOR:

铭牌标贴(自制)

修改序列号格式

修改铭牌材质

修改铭牌尺寸

C

1

2

3

4

变量, 11:年份  01:月份  000001 序列号

序 列 号

 CLEARANCE REQUIREMENTS:
 Combustible Sides: 6” 
 Combustible Back:  6” 
 Serial # 1101000001

Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD-2016
Conforms to NSF / ANSI STD. 4

Lancaster, Pennsylvania                                        

135

135

技术要求:须符合ROHS要求

 

  WARNING 

• Equipment must be installed by a certified technician. Improper installation, adjustment,

  alteration, service, or maintenance of this equipment may cause property damage or

  personal injury and voids warranty. 

• Carefully read and follow the installation and owner's manual prior to equipment installation or use.

• Properly attach the legs provided before appliance is permanently installed and before use.

• Use only on non-combustible countertops and away from any combustible material. 

• Equipment must be installed under proper ventilation as required per local code.

• Conversion to other gas types must be performed by a certified technician only.

This appliance is equipped with a gas pressure regulator. The regulator is factory set at 6” WC for nat, or 10” WC for 

propane. For your safety, call an authorized technician for any gas conversion changes. Do not attempt to make conversion 

changes yourself.
Any changes made by a non-authorized technician voids warranty. This appliance has been regulated for:

                    Natural gas             6” WC factory setting
                         Propane            10” WC factory setting

Note: An authorized technician may convert this unit from one gas type to the other.
Prior to conversion, the unit must be adjusted to the correct gas pressure.

Lighting Instructions

1. Turn all knobs until they are straight up-and-down in the vertical position.

2. Turn on the main valve, and wait 10 seconds to clear the gas for first use.

3. Hold an ignition source (match) at the pilot. When the flame is established, remove the ignition source.

4. Turn the burner knobs to "HIGH". If the burner does not ignite, promptly increase gas flow by continuing to open the pilot valve.

  Do this carefully. If the pilot flame appears larger than necessary, turn it down, and reset the burner ignition.

  The pilot flame should be just large enough to guarantee reliable burner ignition when the knobs are in the vertical position.

Note: To turn off the pilot burner, the gas supply must first be cut off.

铝板

A6061 T=0.8 

阳极发黑

 SAFETY PRECAUTIONS

CAUTION:

 Potential hazard or unsafe practice could result in minor or moderate injury or product or property 

damage. 

NOTICE:

 

• Local codes regarding installation vary greatly from one area to another. The National Fire Protection 

Association, Inc., states in its NFPA96 latest edition that local codes are "Authority Having Jurisdiction" when it 

comes to requirement for installation of equipment. Therefore, installation should comply with all local codes.

• This product is intended for commercial use only. Not for residential use.  

WARNING:

• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• Improper installation, adjustment, alteration, service or maintenance could lead to property damage, injury or 

death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing 

CPG equipment. This manual must be retained for future reference.

• Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user 

smells gas. Safety information can be obtained from your local gas supplier.

• A factory authorized agent should handle all maintenance and repair. Prior to conducting any maintenance or 

repair work contact an authorized service agency.

GAS PRESSURE:

 

The appliance and its individual shutoff valve (to be supplied by user) must be disconnected from the gas supply 

piping system during any pressure testing of that system at test pressures in excess of 1/2 PSI (3.45 kPa). The 

appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve 

during any pressure testing of the gas supply piping system at test pressures equal to or less than 

1/2 PSI (3.45 kPa).

 SERIAL PLATE

NOTE:

 

The serial plate is located 

on the right side of the unit.

Made in China

Item # 351GMCPG36NL

Model # GM36NL
GRILL COUNTER 36" MANUAL

Total BTU: 90,000

Gas Type: Natural Gas

Manifold Pressure: 6" WC

Orifice Size: # 41
CLEARANCE REQUIREMENTS:

Combustible Sides: 6"

Combustible Back: 6"

Serial # 1806002436
Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD-2016

Conforms to NSF / ANSI STD. 4

Summary of Contents for 351GMCPG Series

Page 1: ...USER MANUAL Gas Countertop Griddles MANUAL THERMOSTATIC GRIDDLE MODELS 351GMCPG15NL 351GMCPG72NL 351GTCPG15NL 351GTCPG72NL 3182799 REVISED 3 2020 GMC GTC...

Page 2: ...Performance Group we take pride in the design innovation and quality of our products When used as intended and with proper care and maintenance you will experience years of reliable operation from yo...

Page 3: ...t for installation of equipment Therefore installation should comply with all local codes This product is intended for commercial use only Not for residential use WARNING Do not store or use gasoline...

Page 4: ...ed damage or loss if not apparent until after equipment is uncrated a request for inspection must be made to the carrier within 15 days The carrier should arrange an inspection Be certain to hold all...

Page 5: ...gas line Failure to install a regulator could be potentially hazardous and will void limited equipment warranty 4 Pipe threading compound must be resistant to the action of liquefied petroleum gases C...

Page 6: ...has been pre set at the factory A screwdriver may be required for the initial lighting to adjust the flame for your elevation LIGHTING MAIN BURNER CPG MANUAL GRIDDLES To light burner turn knob to ON...

Page 7: ...y cleaning the griddle must be seasoned again RECOMMENDED CLEANING AGENT Attack tough grease oil and carbon with this ready to use carbonizer and degreaser Its unique formula is designed to clean oven...

Page 8: ...of air Purge gas supply of air pg 5 Air is blowing pilot light out Turn any fans away from the broiler or move to a less breezy location Fat appears to smoke excessively Heat is set too high Turn hea...

Page 9: ...ODEL CODE QTY 1 BURNER 351GMCPG15 06 05 1470672 1 351GMCPG24 2 351GMCPG36 3 351GMCPG48 4 351GMCPG60NL 5 351GMCPG72NL 6 2 REGULATOR 351GMCPG15 01 22 1069501 1 351GMCPG24 351GMCPG36 351GMCPG48 351GMCPG6...

Page 10: ...PG36 3 351GMCPG48 4 351GMCPG60NL 5 351GMCPG72NL 6 6 PILOT VALVE 351GMCPG15 01 20 1068509 1 351GMCPG24 2 351GMCPG36 3 351GMCPG48 4 351GMCPG60NL 5 351GMCPG72NL 6 7 VALVE 351GMCPG15 01 20 1068502 1 351GM...

Page 11: ...CONTINUED THERMOSTATIC GRIDDLE DESCRIPTION MODEL CODE QTY 1 BURNER 351GTCPG15 06 05 1470672 1 351GTCPG24 2 351GTCPG36 3 351GTCPG48 4 351GTCPG60NL 5 351GTCPG72NL 6 2 REGULATOR 351GTCPG15 01 22 1069501...

Page 12: ...ASSY 351GTCPG15 06 05 1472204 1 351GTCPG24 2 351GTCPG36 3 351GTCPG48 4 351GTCPG60NL 5 351GTCPG72NL 6 4 ODS INJECTOR 0 45 351GTCPG15 NAT 01 20 1068513 1 351GTCPG24 NAT 2 351GTCPG36 NAT 3 351GTCPG48 NAT...

Page 13: ...CE 351GTCPG15 NAT 01 20 1068641 1 351GTCPG24 NAT 2 351GTCPG36 NAT 3 351GTCPG48 NAT 4 351GTCPG60NL NAT 5 351GTCPG72NL NAT 6 351GTCPG15 LPG 01 20 1068651 1 351GTCPG24 LPG 2 351GTCPG36 LPG 3 351GTCPG48 L...

Reviews: