Rev 3.0 Cod. 00.008.255
9
STAND BY (STOP)
Push and hold the
ESC/SBY
button for 2 seconds during the functioning to put the pump in stand by
mode:
1) It stops dosing
2) Green on led blinks.
3) If the functioning is PROPORTIONAL the display shows:
“Stop 0%”
on the first row and the current
measure on the second row (see figure on the left side)
3) If the functioning is Manual or ON-OFF the display shows:
“Stop”
and the % programmed
frequency on the first row and the current measure on the second row (see figure on the left side)
Push again the
ESC/SBY
button for 2 seconds to return the pump to the programmed functioning
MENU TREE
Push and quickly release
CAL
button during the functioning to
enter into the programming menu.
Push
+
or
-
button to navigate
through the menu.
Push the CAL button to enter the
submenus
LANGUAGE SELECTION
Push and quickly release
CAL
button and then pressing
+
and
–
buttons select the language
choice. Push
CAL
to enter the language submenu and select “
Language English
” by pressing
+
or
-
.
Push
CAL
to confirm the choice and
ESC
to go back in measuring
DELAY START
WHAT IS IT? The delay start
is the time in minutes (0-999min) after the
power on that the pump waits before dosing the chemical product. During
this period of time
the display shows the message “Delay” on the first row
and the measure on the second row (see figure on the left side). During the
delay start the pump can’t dose but it is possible to enter the menu and
modify the parameters and calibrations.
DELAY START EDITING
Push and quickly release
CAL
button and scroll the menu using
+
and
–
buttons till the display shows “
Delay Start
”. Push
CAL
to enter the submenu
and then by pressing
+
and
–
button choice the value in seconds (0-999).
Push
CAL
to confirm and
ESC
to go back in measuring.