CPA EL 10 cl Programming Instructions Manual Download Page 11

Rev 3.0                                                                    Cod. 00.008.255 

11 

POSSIBLE FUNCTIONING   

 

 

  

 

 

There are 3 possible functioning: 

 

Function  Manual:

  constant  dosing  with  a  number  of  impulses  per  minute 

programmed as follows in the next paragraph. 

 

Function Prop: 

dosing proportional to the distance of the measure from the 

setpoint. 

Range of proportionality : 1ppM

 

 

Function  On-Off: 

constant

 

dosing  that  starts  when  the  measure  moves 

away  from  the  setpoint. 

Total  Hysteresis  centered  on  the  setpoint: 

0.1ppM

 

 
PROGRAMMAZIONE DEL FUNZIONAMENTO MANUALE (COSTANTE) E VISUALIZZAZIONE 

 
 

 

 

 

 

Push and quickly release 

CAL

 button and scroll the menu using 

+

 and 

 

buttons till the display shows “

Function Type

”. Push 

CAL 

to enter the 

submenu and then by pressing 

+

 and 

 

button choice “ 

Function Manual

” and 

confirm pressing 

CAL

. The display will show “Freq.” and the % stored in the 

last programming. Modify it by pressing 

+

 and 

 button and confirm the choice 

pressing 

CAL. 

Push 

ESC button 

to esc the menu and go back in measure 

with the Manual functioning just programmed.  
The number of injections of the pump per minute depends on the % 
programmed. For example: 80% means 120 injections per minute i.e. 150 
pulses/min x 0.8 = 120 pulses/min. 

 

In Manual functioning the display shows on the first row 

“Man.” and the % 

frequency programmed. 
The second row shows the measure. 

 

PROGRAMMING OF THE FUNCTIONING  

 

PROGRAMMING AND VISUALIZATION OF ON-OFF ppM FUNCTIONING 

 

 

 

Push and quickly release 

CAL

 button and scroll the menu using 

+

 and 

 buttons 

till  the  display  shows  “

Function  Type

”.  Push 

CAL 

to  enter  the  submenu  and 

then, by pressing 

+

 and 

 

button, choice “

Function On-Off

” and confirm pressing 

CAL

.  

 
 
The display will show the value of setpoint stored in the last programming. Modify 
it by pressing 

+

 and 

 button and confirm the choice pressing 

CAL.  

 
 

The  display

 

will  show  the  direction  of  dosing 

Chorination 

or 

Dechlorination 

stored in the last programming. Choice the direction by 

+

 or 

 button and confirm 

pressing 

CAL.

 

 
 
Select 

Dechlor 

if  you  want  the  pump  to  inject  for  ppM  values  greater  than 

Setpoint. 
Select 

Chlor

 if you want the pump to inject for values of ppM lower than Setpoint. 

 
The display will show the 

of maximum frequency (150pulses/minute) stored in 

the last programming. Modify it by pressing 

+

 and 

 button and confirm the choice 

pressing 

CAL. 

Push 

ESC 

button

 

to  esc  the  menu  and  go  back  in  measure  with 

the 

On-Off

 functioning just programmed.  

 
 
In the On-

Off functioning if the pump is dosing the display shows “

On

” and the 

%

 

frequency  programmed  on  the  first  row,  if  the  pump  doesn’t  dose  the  display 
shows “

Off

” and the 

%

 frequency programmed.  

On the second row the display writes the measure. 

Summary of Contents for EL 10 cl

Page 1: ...MANUALE D USO Ver 00 10 04 2015 C P A s r l POMPE PUMPS POMPES BOMBAS EL 10 cl MANUALE DI PROGRAMMAZIONE IT PROGRAMMING INSTRUCTIONS UK MANUEL DE R GLAGE F MANUAL DE REGULAT ON E...

Page 2: ...O DI LIVELLO STOP DEL DOSAGGIO STAND_BY SEGNALAZIONE DELLA PORTATA ISTANTE PER ISTANTE REGOLAZIONI DELLA CASA FUNZIONAMENTO ON OFF SETPOINT 1 20 ppM VERSO DI DOSAGGIO clorazione FREQUENZA DI INIEZIONE...

Page 3: ...re e rilasciare rapidamente il tasto CAL e scorrere il menu con i tasti e finch sul display appare la scritta della scelta della lingua Premer il tasto CAL e poi con i tasti e scegliere Lingua Italian...

Page 4: ...000cc di prodotto massimo alla contropressione di targa della pompa NB L allarme temporale non ha effetto sul funzionamento manuale MOD l h 1 unit Tempo Allarme 2000cc cc_unit ME3 ppM 04 12 4 66 6cc 3...

Page 5: ...anuale il display scrive sulla prima riga Man e la percentuale di frequenza di iniezione programmata Sulla seconda riga visualizzata la misura PROGRAMMAZIONE DEI FUNZIONAMENTI PROGRAMMAZIONE DEL FUNZI...

Page 6: ...rispetto alla frequenza di iniezioni programmata Sulla seconda riga visualizzata la misura In qualsiasi punto di programmazione se non viene premuto alcun tasto CAL durante 60 secondi la pompa esce da...

Page 7: ...o l installazione della sonda e della pompa e poi tornare ad affinare la calibrazione dopo 24 ore Una volta stabilizzati flusso e pH e controllato che il cloro sia nelle condizioni di concentrazione o...

Page 8: ...ER RESTORING WATER FLOW CONTROL LEVEL CONTROL STOP DOSING STAND_BY REAL TIME FLOW RATE DEFAULT SETTINGS FUNCTIONING ON OFF SETPOINT 1 20 ppM DIRECTION DOSING Chlorination INJECTION FREQUENCY 100 150 i...

Page 9: ...on to enter the submenus LANGUAGE SELECTION Push and quickly release CAL button and then pressing and buttons select the language choice Push CAL to enter the language submenu and select Language Engl...

Page 10: ...and ESC to go back in measuring Example for the calculation of Alarm Time to dose 2 liters 2000cc of chemical at backpressure of the pump nameplate NOTE The time alarm has no effect on Manual mode op...

Page 11: ...on the first row Man and the frequency programmed The second row shows the measure PROGRAMMING OF THE FUNCTIONING PROGRAMMING AND VISUALIZATION OF ON OFF ppM FUNCTIONING Push and quickly release CAL b...

Page 12: ...ow Prop and the actual frequency of dosing that the pump is doing respect to the frequency programmed On the second row the display writes the measure During the programming if you do not push any but...

Page 13: ...er having installed the pump and the probe in the plant and then do the definite calibration after 24 hours of work of the probe After having stabilized the flow and the pH and having stabilized the c...

Page 14: ...DES FLUX DE L EAU CONTR LE DE NIVEAU STOP DE DOSAGE STAND_BY AFFICHAGE DE D BIT INSTANT POUR INSTANT REGLAGE D USINE OP RATION ON OFF POINT DE CONSIGNE 1 20ppM DOSAGE DIRECTION CHLORATION FR QUENCE D...

Page 15: ...OIX DE LA LANGUE Pressez et rel chez rapidement la touche CAL et d filez le menu avec les boutons et jusqu ce que appara t l inscription de le choix de la langue Appuyez sur la touche CAL et avec le b...

Page 16: ...himiques la pression de la plaque signal tique de la pompe REMARQUE Le Temps d Alarme n a aucun effet sur le type de Op ration Manuel MOD l h 1 unit Tempe Alarme 2000cc cc_unit ME3 ppM 04 12 4 66 6cc...

Page 17: ...d injection programm e La deuxi me ligne montre la mesure PROGRAMMATION DU TYPE D OP RATION PROGRAMMATION DU FONCTIONNEMENT ON OFF ppM ET VISUALISATION Pressez et rel chez rapidement la touche CAL et...

Page 18: ...l affichage crit sur la premi re ligne Prop et la de la fr quence d injections que l aimant fait par rapport la fr quence des injections programm e La deuxi me ligne montre la mesure En n importe que...

Page 19: ...e la sonde et de la pompe puis revenir en arri re pour affiner le calibrage apr s 24 heures Une fois stabilis s d bit et le pH et v rifier que le chlore est dans les conditions optimales de concentrat...

Page 20: ...L DEL FLUJO DE AGUA CONTROL DE NIVEL STOP DE DOSIFICACI N STAND BY SE AL DE CAUDAL INSTANT NEO VALORES DE F BRICA FUNCIONAMENTO ON OFF SETPOINT 1 20ppM DIRECCI N DE DOSIFICACI N Chlor cloraci n FRECUE...

Page 21: ...r en el submenu SELECCI N DE LENGUAJE Comprimir y suelte r pidamente la tecla CAL y moverse por el menu con las teclas y hasta que el display muestra la selecci n de idioma Pulse CAL y luego las tecla...

Page 22: ...i n de 2 litros 2000cc de qu micos a la presi n de la placa de la bomba NOTA El tiempo de alarma no tiene ning n efecto en el tipo de operaci n manual MOD l h 1 unit Tiempo Alarma 2000cc cc_unit ME3 p...

Page 23: ...el display escribe en la primera l nea Man y el porcentaje de frecuencia de las inyecciones programada La segunda l nea muestra la medida PROGRAMACI N DE LA OPERACI N PROGRAMACI N DE LA OPERACI N ON...

Page 24: ...ntaje de inyecciones que la bomba hacie en comparaci n con la frecuencia de las inyecciones programadas En cualquier punto de programaci n si no es comprimido ninguna tecla CAL durante 60 segundos la...

Page 25: ...n de la sonda y de la bomba y luego volver a refinar la calibraci n despu s de 24 horas Una vez estabilizado el flujo y control de pH y la concentraci n de cloro es en las condiciones ptimas proceder...

Page 26: ...zione dell acido ipocloroso in funzione del pH UK Dissociation curve of hypochlorous acid as a function of pH F Courbe de dissociation de l acide hypochloreux en fonction du pH E Curva de disociaci n...

Reviews: