40542-A REAR REGISTER KIT (Optional Accessory)
INSTALLATION INSTRUCTIONS FOR GRAVITY VENTED WALL FURNACES
STEP 1.
Cut hole within stud space behind heater in the back wall 8-1/4” high by 12-5/8” wide. The lower
edge of the hole to be 45-3/4” above the floor plate or 47” from the floor (with standard 2”x4”
floor base) as shown in Figure 13.
STEP 2.
Install plaster ground frame for rear register in hole and nail frame to stud as shown in Figure 14.
STEP 3.
REAR REGISTER INSTALLATION: Cut and remove embossed plates in inner and outer casing.
Follow instructions for installation of regular furnace.
STEP 4.
After furnace is installed, attach rear register grille as shown in Figures 16 & 17 by insertion over
plaster ground and attach with sheet metal screws, provided.
STEP 5.
Damper as shown in Figure 17 can be adjusted from full open for maximum heat to fully closed.