29
- If you hear a snapping sound, can you see a spark at the
electrodes?
Note: You will need to remove your cooking grates and heat
control grids to see the electrodes. The electrodes should have a
1/8” to ¼” gap between the electrode and contact point.
•
Check for loose wire connections to the igniter or electrodes.
•
Check to see if debris is blocking the electrodes.
•
If the igniter is not working, can you light the grill with a lighter?
Flare-ups
•
Check heat control grids and cooking grates for excess food or
grease build-up.
•
Ensure grill is not placed directly in the path of wind.
Be sure drip tray is clean (do not use aluminum foil on drip tray.)
Note: Some flare-ups may be inevitable if cooking greasy foods.
Yellow Flames
•
Check the burner inlet for obstructions, particularly at air inlets for
each burner.
•
Grill may be in an area that is too windy.
Flame blows out on low setting or
has uneven heat distribution.
•
Check for spider webs or insect nest in venturi and clean venturi.
•
Cold grill needs to be preheated for 5 minutes on high setting.
•
Venturi may be misaligned and needs to be lined up over orifices.
•
Cold and windy weather will require you to move grill away from
the wind.
•
Lack of fuel. Check to see cylinder valve is open and cylinder has
fuel.
Low heat with the knob on “HIGH”
•
Check to see if the fuel hose is bent or kinked.
•
Make sure the grill area is clear of dust.
•
Check your gas supply and gas pressure.
•
If it is only one burner that appears low, make sure the orifice or
burner is clean.
Grill is Too Hot
•
Excess grease build-up causing grease fires.
•
Damaged or faulty regulator.
Replace with factory authorized parts.
•
Cook on a lower temperature setting.
Flame behind control panel or
control knob area.
IMMEDIATELY shut off cylinder valve and allow grill to cool.
•
C
heck for spider webs or insect nest in venturi and clean venturi.
•
Gas is leaking from a faulty connection. Tighten connections with
an adjustable wrench and replace damaged parts. Perform a leak
test on all connections before cooking on grill again.
•
Venturi may be misaligned and needs to be lined up over orifice.
•
If you cannot find the reason, call Customer Service at
855-520-1559 for assistance.
Fire at any connection.
IMMEDIATELY shut off cylinder valve and allow grill to cool.
•
Gas is leaking from a faulty connection. Tighten connections with
an adjustable wrench and replace damaged parts.
•
Perform a leak test on all connections before cooking on grill again.
•
If you cannot find the reason, call Customer Service at
855-520-1559 for assistance.
Summary of Contents for C Series
Page 31: ...30 C2C34 Exploded Parts View ...
Page 33: ...32 C2C36 Exploded Parts View ...
Page 35: ...34 C2C42 Exploded Parts View ...
Page 37: ...36 C2SL30 C2SL30 FS Exploded Parts Diagram ...
Page 40: ...39 ...