14
x
The system has a flow limiting device which, when activated, will limit the flow of gas to 10 cubic feet per
hour.
x
NEVER
use grill without leak testing this connection.
LP (Propane) Gas Supply Connection
1.
The tank valve should be in the “OFF” position. If not, turn the knob
clockwise until it stops.
2.
Make sure all burner valves are in the “OFF” position.
3.
Always connect the gas supply regulator as follows:
Insert the regulator inlet into the tank valve and turn the coupling nut
clockwise until the coupler tightens up (see picture). Do not over-tighten the
coupler. Turn the main tank valve on, and turn the burner control valves on
the unit to the “HIGH” position for about 20 seconds to allow the air in the
system to purge before attempting to light the burners.
Pre-Operation Leak Testing
1.
Do not insert any tool into the valve outlet or safety relief valve. You may damage the valve and cause a
leak. Leaking propane may result in explosion, fire, severe personal injury, or death.
2.
If a leak is detected at any time, or you cannot stop a gas leak, immediately close the tank’s shut-off valve
(gas supply from LP tank to the Grill) and call LP gas supplier or your fire department!
3.
Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the
regulator. Have a qualified service technician leak test the grill any time a part of the gas system is
replaced.
Never attempt to attach this grill to the self-contained LP gas system. Do not use the grill until leak testing has
been completed.
Leak Testing Valves, Hose and Regulator
1. NEVER smoke while leak testing.
2. Extinguish all open flames. Never leak test with an
open flame.
3. Mix a solution of equal parts mild detergent or liquid
soap and water.
4. Turn all grill control knobs to OFF.
5. Ensure that the connections from the regulator to the
grill and tank are tight and secure (see picture).
6. Completely open LP tank valve by turning cylinder
valve knob counterclockwise (right to left). If you hear
a rushing sound, turn gas off immediately. There is a
major leak at the connection. Correct before
Summary of Contents for C Series
Page 31: ...30 C2C34 Exploded Parts View ...
Page 33: ...32 C2C36 Exploded Parts View ...
Page 35: ...34 C2C42 Exploded Parts View ...
Page 37: ...36 C2SL30 C2SL30 FS Exploded Parts Diagram ...
Page 40: ...39 ...