We see temperature and temperature differences!!!
8
CG320 & CG640 Manual
the package.
Rated power of adaptor included in the package is 12VDC, 3.33A.
⑤
About 20 seconds later power supplied to the camera, image shall be displayed in the monitor.
⑥
Adjust the focus of lens
Manual focus lens: manually turn focus ring of lens to get the right point of focus.
Motorized focus lens: Enter SYSTEM Tab in OSD menu to adjust focus of motorized lens or zoom
lens.
⑦
Using jog switch, control OSD menu to set parameters of cameras as required.
User can control OSD menu using jog switch on the rear of the camera or user can control it by
RS485 communication when jog switch cannot be used in the field.
Refer to pages from 8 of this manual for OSD menu control by jog switch.
Refer to page 16 of this manual to know how to use jog switch.
For control via IP network, refer to thermal imaging analyzer or camera controller on CD included
in the package.
Control via RS-485 communication
User can control OSD menu via RS-485 communication.
(1) Control on PC (use Pelco-D protocol or Thermal Protocol)
Connect RS-485 terminals on the rear of camera to PC using RS-485 converter (USB to
RS-485 converter or Ethernet to RS-485 converter).
Example) USB port or Ethernet port on PC
→ RS
-485 converter
→ RS
-485
terminal (“+” and “–“)
(2) Control using key board controller (by Pelco-D Protocol)
Connect TRX “+” and TRX “
-
“ connection terminals of key board controller to
RS-485 terminals
(RS-485
“
+
” and
RS-485
“
-
“
) on the rear of camera.
Key board controller
RS-485 terminals on the camera
(+) terminal (TRX+)
RS-485+
(-) terminal (TRX-)
RS-485-
Control OSD menu while user sees monitor.
⑧