We see temperature and temperature differences!!!
38
CG320 & CG640 Manual
①
TEMPERATURE MODE: Set temperature detection mode, between normal and high detection modes.
NORMAL: Measure temperature of object between -
20℃
and
120℃.
In case camera is calibrated for measuring temperature from -
20℃ to 120℃ in the last process
of production, the camera cannot measure temperature over this range like the camera with high
temperature detection mode.
HIGH (option): Measure temperat
ure of objects between 0℃ and 500℃.
If COX camera is delivered with high temperature detection mode, user can select NORMAL or
HIGH mode (dual mode), depending on temperature measurement range.
NORMAL (normal temperature detection mode) mode is recommended in case measurement
range is from -
20℃ to 120℃
for more accuracy in measurement and also for better image quality.
Accuracy of measuring temperature between -
20℃
and
120℃
at HIGH (high temperature
detection mode) mode is a little lower than measuring at NORMAL mode and image quality is
also poor.
Medical (option): Measure temperature of objects between 20
℃ and 50℃.
Mainly used for medical devices or detecting fever in public area like airport.