12-3) Internal parameter setting program
(1) Connection
(1) Holding current setting
- It is to set the port after having checked the COM port
- It is to set the size of current supplied
- If "Connect" button is pressed and the normal connection
- It can be set in the range of 0 ~ 90 [%].
is made, the connection success message appears
(2) Driving current setting
(2) Data verification
- It is to set the size of current supplied to the
- If “READ” button is pressed after properly connected, the value motor during operation.
currently set in the driver will be displayed on the right.
- The setting range varies by motor and will be
automatically displayed according to a motor set
(3) Data correction / Save
- You can modify the set value of the desired function
at the user function setting on the right side of screen.
(3) Input / Output operation level setting
- If you press “WRITE” button after having modified
- It is to set the operation level of input and
the desired value, the set value will be saved in the driver.
output signals of driver.
- “0” in setting means Active Low operation and
(4) Application of the set value
“1” means Active High operation.
- The revised value will be applied once the driver power
is turned off and turned on again after the setting of
revised value has been completed.
in the driver.
connected with a device.
in the dialog box.
when the motor stops.
Description of user function setting
How to use
Plustep internal parameter setting program can be
downloaded from the homepage
WWW.COWINFA.COM
When connecting PLUSTEP driver and PC,
conversion connector is required.
It is being sold.