background image

10

 

The summary for the proper installation of the water filtration device

Please check before use!

This product is for 120 V   60 Hz only .

Please connect the power plug to a dedicated grounded electrical 

outlet for 120 V   60 Hz. The water filtration device works normally 

only when the electricity is connected.

•  Open the main water supply valve.

The main water must be supplied to operate the water filtration device normally.

•  After installing the product

Get rid of the saved water above the full water in the inner water tank 2 times or more to use.

•  When the indicator in the indication part is turned off

When the indicator in the indication part is turned off, check if the power supply was stopped 

due to the power failure or other cause.

•  Regularly filter replacement

It is important to replace the filter regularly to drink the pure water. If the filter is overused 

beyond its service life, the performance of the water filtration device deteriorate, Do not miss the 

filter replacement cycle.

•  When you didn’t use for a long time

If you saved the water for a long time or you didn’t use, drain the water inside of the water 

filtration device completely and remove the newly filtered water one time to use.

•  When you don’t want to use for a long time

Close the main water supply valve and unplug.

When you don’t use for a long time, close the main water supply valve and unplug.

Tips

INST
ALL
ATION PREC

AUTIONS

h

ow t

o U
se

Summary of Contents for CP-07BLO

Page 1: ...This product can not be used if the voltage is different from that mentioned in the rating plate For your safety and proper use of the product please read this User s Manual before use Warranty card i...

Page 2: ...d water temperature lowers to excess 4 Attachable gutter It can take a lot of water at a time using the big vessel by applying the attachable gutter 1 Power saving mode using the light sensor If you p...

Page 3: ...te as verified and substantiated by test data See performance data sheet for individual contaminants and reduction performance This system is acceptable for treatment for influent concentrations of no...

Page 4: ...wet carefully unplug the unit and let the electric outlet completely dry before subsequent use Otherwise electric shock or fire may occur as a result Do not pull the power cord Otherwise electric shoc...

Page 5: ...ower cord at your discretion Otherwise electric shock or fire may occur as a result Do not install near a heating device Otherwise fire may occur as a result Do not place or use the Inflammable gases...

Page 6: ...dd smell immediately unplug from the electrical outlet and call our Service Center Otherwise electric shock or fire may occur as a result Do not put the candle a light for cigarette on the products Ot...

Page 7: ...erial In some cases fishes might even die Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Do not repair disassembl...

Page 8: ...7 PARTS NAME Indication part Operation part Room water extraction faucet Cold water extraction faucet Cup touch lever Gutter Front Cooling Stopper Radiator Power cord Inlet Orange Outlet Blue Rear...

Page 9: ...s such as pentavalent arsenic barium cadmium selenium radium 226 228 trivalent chromium hexavalent chromium lead nitrate nitrite This inno sense filter has the functions to reduce smell induction mate...

Page 10: ...fore Connection 1 Close main water supply valve to separate the faucet 2 Wind the teflon tape on the adaptor and fit it to the pipe 4 Connect 1 4 inch orange tubing with the connector on the adaptor 3...

Page 11: ...art is turned off check if the power supply was stopped due to the power failure or other cause Regularly filter replacement It is important to replace the filter regularly to drink the pure water If...

Page 12: ...lamp is flashing when the power saving mode is on and the compressor operates 7 Power indicator When you connect the power the indicator is turned on 6 Light sensor It is the sensor sensing the light...

Page 13: ...and about 1 hour is passed If you press the SAVE in the right of the control button as the power saving mode indicator is turned on and the number of the compressor driving is decreased the electrici...

Page 14: ...faucet Please push the cup touch lever in the cold water faucet To drink the room water To drink the cold water If the cold water doesn t come from the water filtration device check if the cold water...

Page 15: ...nge Outlet tubing Blue 1 cooling stopper 120 V 60 Hz Only Main water supply valve Connect the orange color inlet tubing 1 to the tap water supplying pipe Connecting the outlet tubing 2 1 2 HOW TO USE...

Page 16: ...r more necessarily after installing Cold water plumbing Please connect to the cold water pipe necessarily If you connect to the warm water pipe the filter can be damaged Movement and installation When...

Page 17: ...2 Please drain and take the water inside of the water filtration device completely using the draining hose 3 Open the upper cover of the product and open the storage tank cover 1 Unplug the power cor...

Page 18: ...aining completely using the draining hose and emptying the newly room water one time or more 5 Please wipe the surface of the storage tank with soft clothes 8 Open the main water supply valve after cl...

Page 19: ...r sticking to the product Gutter Close the storage tank cover completely A worm or a foreign body can be entered When you clean the storage tank don t use the medicine or the detergent If you don t cl...

Page 20: ...shortened rater than the expected replacement cycle The period for the filter exchange is made based on 10 L use in a day for house use 4 people based and 20 L use for business CP 07BLO About filter r...

Page 21: ...and separate the gutter in the front side 3 Please lift the cup touch lever up after closing the faucet using the faucet cap As the water can be remained inside of the water filtration device please...

Page 22: ...over and close the upper cover of the product after tightening 2 fixed screws in the front of the product using the driver By changing the filter and connecting the fitting and the hose precisely chec...

Page 23: ...e indicator lightened Please press the cold water mode selection button Didn t you close the main water supply valve If it is the low water level to protect the electric motor the cooling function doe...

Page 24: ...g Pressure 138 kPa 827 kPa Net Weight 17 4 kg The water amount can be differentiated according to the water pressure and the water temperature The water tank capacity is the amount by the size and can...

Page 25: ...24 WATER FLOW DIAGRAM CP 07BLO SPECIFICATION WATER FLOW DIAGRAM Others...

Page 26: ...5 83 7 Selenium 0 05 0 117 0 003 96 0 97 8 TDS 187 5 737 6 51 6 89 9 93 0 Aesthetic Chlorine 50 2 07 0 56 54 53 72 8 VOC 95 reduction 0 32 0 0077 95 70 97 6 While testing was performed under laborator...

Page 27: ...COST US WJNF8 S NEO SENSE FILTER 6 7 84 WJMF8 20 S RO MEMBRANE FILTER 20 60 92 WJIF8 S INNO SENSE FILTER 18 9 40 WJCC 02 CERAMIC FILTER 12 3 6 ARSENIC FACTS Arsenic abbreviated As is found naturally i...

Page 28: ...055 99 0 000013 methoxychlor 0 04 0 050 99 0 00013 pentachlorophenol 0 001 0 096 99 0 0013 simazine 0 004 0 120 97 0 0043 styrene 0 1 0 150 99 0 00053 1 1 2 2 tetrachloroethane 0 081 99 0 0013 tetrac...

Page 29: ...2 Trichloroethane p Dichlorobenzene 1 1 1 Trichloro 2 Propanone Trichloroethylene 1 2 Dichloroethane Heptachlor Trihalomethanes THMs 1 1 Dichloroethylene Heptachlor Epoxide Bromodichloromethane cis 1...

Page 30: ...any kind even if arising from a breach of this Warranty Limitations and Exclusions TO THE EXTENT PERMITTED BY APPLICABLE LAW COWAY DISCLAIMS ANY OTHER WARRANTY EXPRESS OR IMPLIED THAN THAT PROVIDED F...

Page 31: ...the Product covered by this Warranty within thirty 30 days following such failure d There has been no misuse abuse or negligence with respect to the Product on the part of the OWNER Waiver COWAY s fa...

Page 32: ...http www coway com MADE IN KOREA 1208828 001...