10
5. CONDITIONS OF USE
Electrical Supply
●
A constant 110v supply is critical for operation
●
If operating from a generator ensure that this is rated at 10KVA or if using a
transformer use minimum 5KVA
●
Ensure supply lead is a maximum length of 10m
Range of Intended Environmental Conditions:
Do not use the conveyor outside the following environmental conditions:
●
Ambient temperature: -10°c -+40°c
●
Wind Speeds: 0 – 50MPH
Prohibited Applications
Do not use the conveyor if any part is:
●
Submerged in water.
●
In an explosive atmosphere.
●
In a corrosive atmosphere or environment.
Prohibited Materials
●
Solely Liquids.
●
Reinforcing bar or metal rod.
●
Items longer than 500mm.
●
Lumps weighing greater than 30kg or measuring greater than 300mm x 200mm x 200mm.
●
Heated materials above 60°c.
●
Substances corrosive to rubber or metal.
●
Materials likely to puncture the belt.
●
Polymers or lubricating substances.
●
Asphalt or adhesive substances likely to stick to the conveyor following use.
Conveyor Sound Levels:
●
Decibel Rating 60-65db
.