![Courtyard 51161 Manual Download Page 12](http://html1.mh-extra.com/html/courtyard/51161/51161_manual_2673291012.webp)
Problem
Cause
Solution
Gas valve may be off
Turn the gas valve on
Gas tank may be empty
Refill the gas tank
Orifice may be blocked
Clean out the orifice
Air is within supply system
Pump out air from all lines
Loose connection
Check all fittings and tighten connections
as necessary
Debris around the pilot
Clean out the debris
Loose connection
Check all fittings and tighten connections
as necessary
Thermocouple is bad
Call for a replacement part and replace
the thermocouple
Gas leak within the line
Check all connections; call for a
replacement part if anything is damaged
Lack of gas pressure
Gas tank is almost empty
Gas pressure is low
Gas tank is almost empty
Orifice may be blocked
Clean out the orifice
Control knob isn’t on
Turn the control knob on
Thermocouple is bad
Call for a replacement part and replace
the thermocouple
Pilot light assembly is bent or not in the
correct location
Place pilot light in the correct location
and retry lighting procedure
Pilot won’t light
Pilot won’t stay on
Burner won’t light
TROUBLESHOOTING
Bond Manufacturing Co., Inc. | Page 12