Error
Code #
Error Message
27
TIMEOUT_ON_CLOSE
(Added in Ver 1.09) - Error 27 occurs when specific Hoistway Doors do not reach
FULL CLOSE (actual physical stall), or the iLEARN does not receive sufficient information from the Close iS-
ENSOR to indicate FULL CLOSE within an alloted time.
Hoistway Door Timeouts occur as follows: If after 10s the iSENSOR magnet is not discovered, the doors go
to slow speed. If after another 10s the “creep position” is not found, the doors go to creep speed. If after 30s
total, the FULL CLOSE position has not been found then a “TIMEOUT_ON_CLOSE” fault is generated. At this
point, the iLEARN Control will reset the stall position of the corresponding iSENSOR. The hoistway doors will
travel at “creep” speed until the iSENSOR magnet is found and a new FULL CLOSE position is identified by the
iLEARN System.
Check the physical condition of the Door Panels and tracks. Make sure there are no physical barriers which
prevent the Hoistway Doors from reaching FULL CLOSE. Check the physical condition of the CLOSE iSEN-
SOR and iSENSOR Magnet. Replace if damaged.
28
GATE_ERROR_EXPANSION_MODULE_FAULT
(Added in Ver. 2.0) - Error 28 indicates that the
iDRIVE.G Car Top Controller is not communicating with the Car Top Expansion Module.
Check the CANbus cable between the iDRIVE.G VFD Control and the Car Top Expansion Module.
29
GATE_ERROR_ENCODER_FAULT
(Added in Ver. 2.0) - Error 29 indicates that the current Car Gate’s
FULL OPEN position is greater than 110% of the “learned” FULL OPEN position.
Run the Gate SetUp Wizard to re-establish the Car Gate’s “learned” FULL OPEN position.
30
GATE_ERROR_TIMEOUT
(Added in Ver. 2.0) - Error 30 occurs when a Car Gate does not reach FULL
OPEN or FULL CLOSE within an alloted time (30s).
Check the physical condition of the Car Gate, Gate Shoes, and Gate Motor. Run the Gate Setup Wizard to re-
establish the Car Gate’s “learned” FULL OPEN and FULL CLOSE position.
31
iLEARN_EVENT_REVERSING EVENT
(Added in Ver. 2.0) - A reversing event occured.
32
iLEARN_EVENT_CURTAIN1_REVERSE
(Added in Ver. 2.0) - A reversing event occured at Light
Curtain #1
33
iLEARN_EVENT_CURTAIN2_REVERSE
(Added in Ver. 2.0) - A reversing event occured at Light
Curtain #2
34
iLEARN_EVENT_SHOE_REVERSE
(Added in Ver. 2.0) - A reversing event occured at Reversing Edge
35
iLEARN_EVENT_EUD
(Added in Ver. 2.0) - EUD opened
36
iLEARN_EVENT_RESET_PRESSED
(Added in Ver. 2.0) - iDRIVE.G Car Top Control was locked out
of operation and Car Reset Button was pressed to unlock it
37
GATE_ERROR_MOTOR_FAULT
(Added in Ver. 2.0) - IDRIVE.G Car Top Control reported a motor fault.
Inspect Motor Fault Bits to find more specific information.
38
iLEARN_EVENT_INS_LOW
(Added in Ver. 2.3) - iLEARN lost Inspection Input from Elevator Control
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...