Metiri™ Scientific COUMET60100SB
Metiri™ Hobbyist COUMET60100HB
Smart Energy Meter
Users Manual for Firmware ver: 0.8.8
QUICK PRODUCT EXPLAINATION
1.
LCD
: Back-lit primary display.
2.
Select Button
: Touch sensitive button with LED touch indicator. Press to scroll through data options or Smart
Graph.
3.
Enter Button
: Touch sensitive button with LED touch indicator. Press to return to the main screen. If on the
main screen, will scroll through set-up options.
4.
Aux. Power
: Female socket for device auxilliary power, 5.0Vdc +/-10%. Compatable with USB mini-B Plug.
5.
MicroSD Slot (Scientific Model Only)
: Card slot for recording of measured values. Can accept standard
microSD flash memory formated with FAT32. Metiri™-S will automatically detect card, create a CVS file, and
start writing measured data.
6.
Source Wires
: Connect to power source or battery up to +60Vdc. Current flowing from Source to Load is
considered positive current. Forward continuous current should never exceed 70 amperes.
7.
Load Wires
: Connect to power load or battery up to +60Vdc. Current flowing from Load to Source is
considered negative current. Negative continuous current should never exceed 70 amperes.
8.
In Line Fuse (Sold Separately)
: The Metiri™ products do not provide protection against too much current
flowing through it. A fuse installed in series with the positive Source Wire is required. Current flowing through
the Metiri™ product should never exceed the current specified in the Safe Operating Area graph.