![Cotech Cocraft HI2000 Original Instructions Manual Download Page 12](http://html1.mh-extra.com/html/cotech/cocraft-hi2000/cocraft-hi2000_original-instructions-manual_2672610012.webp)
12
EN
G
LI
SH
Storage
Long-term storage of the generator will require some additional preventative measures to guard against
deterioration and ensure that it works well when it is used again.
1. Let the generator cool down. Empty the fuel system. Refer to the
Emptying the fuel system
section.
2. Unscrew the spark plug and pour a tablespoonful of engine oil (10W-30 in the summer and 5W-30 in the winter) into
the spark plug hole.
3. Check the engine oil level and top-up the oil tank if necessary.
4. Pull the starter handle a few times to distribute the oil in the cylinder, then refit the spark plug. Do NOT reconnect
the spark plug cap.
5. Pull the starter handle a few times until you feel a slight resistance, then slowly allow the starter cord to recoil.
6. Clean the exterior of the generator.
7. Store the generator indoors, in a dry and well-ventilated room. Do not cover the generator with a plastic sheet or dust
cover. Non-porous covers will trap moisture around the generator and assist corrosion.
Warning:
If you choose to store the generator with fuel in the tank, consider the following advice:
• Do not store the generator in a room where there is any type of heater or appliance with a pilot light which could ignite
petrol fumes. Also avoid any area containing spark-producing electric motors or where power tools are operated.
• Avoid storing the generator in areas with high humidity, because that promotes corrosion.
• Leave the engine switch/fuel cut-off valve in the
0 OFF
position.
• Place the generator on a firm level surface. Tilting can cause the fuel to leak out.
When removing the generator from storage:
• Check the generator as described in section
Preparations
. Refuel with fresh petrol.
Responsible disposal
This symbol indicates that this product should not be disposed of with general household waste. This applies
throughout the entire EU. In order to prevent any harm to the environment or health hazards caused by
incorrect waste disposal, the product must be handed in for recycling so that the material can be disposed
of in a responsible manner. When recycling your product, take it to your local collection facility or contact
the place of purchase. They will ensure that the product is disposed of in an environmentally sound manner.
Troubleshooting guide
Trouble
Possible cause
Action
The engine
does
not start.
Low engine
output.
The engine
runs
erratically.
Insufficient
compression.
Loose spark plug.
Tighten.
Loose cylinder head bolt.
Tighten.
Damaged cylinder head gasket.
Replace gasket.
Sufficient com-
pression.
Fuel system
problem: no fuel
supplied to com-
bustion chamber.
Choke not applied.
Apply the choke.
Starter handle pulled too slowly.
Pull starter handle
more sharply.
Foreign matter in tank.
Clean the tank.
Clogged fuel line.
Clean the fuel line.
Fuel tank empty.
Add fuel.
Fuel cut-off valve or air vent closed.
Open.
Electrical system
problem: fuel
supplied to com-
bustion chamber.
Insufficient
spark.
Spark plug dirty
or wet.
Clean.
Faulty spark plug.
Change spark plug.
Faulty magnet.
Contact our
customer services.
Spark okay.
Carburettor
set up wrong.
Starter handle
pulled too slowly.
Pull starter handle
more sharply.
Wrong type of fuel used.
Check.
Overloading.
Check the rated power.