16
17
TROUBLESHOOTING
2
)
Low ice production
Problem
Inspection Project Possible Reasons
Solution
Increase water
pressure
The water pressure is
too low, and the water
supply time is long.
Water pressure of
water supply
Water
temperature
reduction
High water
temperature
water temperature
Suitable
temperature
setting
The ambient
temperature is too
high or too low.
ambient temperature
Contact
after-sales
service personnel
Refrigerant leakage
Replacement of
inlet valve
Leakage makes
cooling time longer.
Cryogen
Inlet valve
Cleaning
condenser
Too much ash
accumulation in
condenser results in
bad inlet air, high
condensation
temperature and long
ice making time.
condenser
Cleaning or
replacing filter
screen
The blockage of the
filter leads to poor
water flow.
Filter screen
Ice making
time is too
long.
No ice or
thin ice.
Change the water
pump
Poor water flow due
to pump failure
Water pump
The ambient
temperature is
too high.
The ambient
temperature is too
high.
ambient
temperature
At least 6FT space
left and rear.
Poor intake air leads
to high condensation
temperature and
long ice making
time.
Air inlet
TECHNICAL PARAMETER
Model
Rated Voltage
Rated Frequency
Refrigerant
Rated Current
Vesicant
FP10096US
(
YD-Z63
)
120V
60Hz
R290a/72g
2.5A
C5H10