10. CHANGING PRODUCT FLOW DIRECTION FROM LR TO RL
WARNING: Always unplug and remove power source before working on or around
the machine. Only qualified trained service personnel are to perform
the
procedure.
FOLLOW STEPS BELOW
STEP 1
Unplug and remove power source.
STEP 2
Remove motor cover.
STEP 3
Remove the white power lead wire on the capacitor from the
negative (-blue wire) terminal and connect it to the positive
(+red wire) terminal of the capacitor.
STEP 4
Replace motor cover.
NOTE: DO NOT twist belt to reverse product flow; belt will rub the frame and wear
out rapidly if twisted.