9. Specifications 

 

 

Model XP-704III 

Target Gas 

R-22, R-32, R-404A, R-407C, R-600a, R-410A, R-134a, R-290, HFO-1234yf 

Detection Principle  Hot-wire semiconductor sensor (Refer to page 22.) 

Gas Sampling 

Method 

Extractive type 

Detectable Leak 

Rate (annual) 

R-22: 2.84[g], R-32: 1.71[g], R-404A: 3.30[g], R-407C: 3.12[g], R-600a: 1.91[g] 

R-410A: 2.82[g], R-134a: 20.09[g], R-290: 1.45[g], HFO-1234yf: 3.74[g] 

Detectable Gas 

Concentration 

5 ppm (R-134a: 30ppm) 

Response Time

 

Within 10 seconds 

Rated Power 

Supply 

Size AA alkaline batteries (LR6) x 2 

Battery Life 

*1

 

Approx. 12 hours (with size AA alkaline batteries at 25 degrees C) 

Degree of 

Protection 

*2

 

Equivalent to IP22 

*3

 

Operating Pressure 

Range 

Atmospheric pressure (800 to 1100 hPa) 

Operating 

Temperature and 

Humidity Range 

0 to 40 degrees C 

Less than 85% RH (with no condensation) 

Dimensions 

Approx. 38 (W) x 130 (H) x 32 (D) mm (excluding protrusions) 

Weight 

Approx. 190g (including batteries and soft case) 

 

*1: The battery life may vary based on the environmental conditions, operating conditions, 

storage time, battery manufacturer, etc. 

*2: While the Gas Leak Detector is inside the soft case. 

*3: “Equivalent to IP22” means that protection is provided against the approach of a finger to 

any hazardous product location (IP2x) and that protection is provided against the 

negative influence on the product interior from water drops falling within 15 degrees of 

perpendicular on both sides of the exterior of the product for 2.5 minutes each in four 

location (for a total of 10 minutes) (IPx2). 

 

- 20 -

 

 

8. Warranty 

 

 

New Cosmos Electric Company Limited (New Cosmos) offers the following as the sole and 

exclusive limited warranty available to Customer. 

This warranty is in lieu of, and customer waives, all other warranties of any kind or nature, 

expressed or implied, including without limitation, any warranty for merchantability or 

fitness for a particular purpose. The remedies set forth herein are exclusive. 

 

New Cosmos warrants to the original purchaser and no other person or entity (customer) 

that gas detection product supplied by New Cosmos shall be free from defects in materials 

and workmanship for a period of one (1) year from the date of purchase. This warranty 

does not include consumables, such as fuses, filters, etc. Certain other accessories not 

specifically listed here may have different warranty periods.   

 

After examination of allegedly defective product return to New Cosmos, with freight prepaid, 

should the product fail to conform to this warranty, customer’s only remedy and New 

Cosmos’s only obligation shall be, at New Cosmos’s sole option, replacement or repair of 

such non-conforming product or refund of the original purchase price of the 

non-conforming product. In no event will New Cosmos be liable for any other special, 

incidental or consequential damages or losses of any kind whatsoever, including but not 

limited to, loss of anticipated profits and any other loss caused by reason of non-operation 

of the product. 

 

This warranty is valid only if the product is maintained and used in accordance with New 

Cosmos’s instructions and /or recommendations. New Cosmos shall be released from all 

obligations under this warranty in the event repairs or modifications are made by persons 

other than its own or authorized service personnel or if the warranty claim results from 

physical abuse or misuse of the product. 

 

Summary of Contents for XP-704 III

Page 1: ...Keep this instruction manual available for quick reference when needed Read this instruction manual and thoroughly understand before using the product HCFC Detector...

Page 2: ...11 Deactivating the Alarm Buzzer 12 Lighting the Backlight 12 4 Error Displays 13 5 Replacement of Consumable Parts 14 Filter Element Replacement 14 Dust Filter Replacement 15 Battery Replacement 16 6...

Page 3: ...ew Cosmos distributor Replacements for any missing or damaged items will be sent Options Sold Separately 1 1 Refer to page 18 for details of options Name Quantity Gas Leak Detector with soft case 1 DF...

Page 4: ...horoughly this Instruction Manual regardless of your experience with using Gas Leak Detectors Do not use this Gas Leak Detector for improper purpose Do not use this Gas Leak Detector in undocumented w...

Page 5: ...eplace batteries if the batteries are leaking when the remaining battery charge is low To avoid damaging its performance never attempt to disassemble alter or change the structure or electric circuits...

Page 6: ...4 2 Part Names and Functions 8 1 2 11 7 9 5 4 10 6 3 12...

Page 7: ...hing frequency increases as the concentration of the gas leak increases The lamps light if the concentration is very high These lamps also flash when an error occurs in the pump or sensor 9 Buzzer hol...

Page 8: ...6 No Name Functions 1 Side Zipper Open the zipper to replace the batteries 2 Back Pocket The Operating Guide is stored here 3 Inside Pocket A Replacement Filter Element is stored here Soft case 1 3 2...

Page 9: ...up both sides and close the Velcro The Gas Leak Detector is in the soft case at the time of shipment from the factory 2 Insert AT 2 Gas Probe to DF 114 Drain Filter AT 2 Gas Probe is inserted to DF 11...

Page 10: ...nsitivity level 3 Before warm up is completed the highest sensitivity level 0 lamp will flash The maximum warm up is three minutes Always perform a daily check before using the Gas Leak Detector Refer...

Page 11: ...ion sensitivity level is decreased beyond 1 the level will return to level 5 To Increase the Detection sensitivity level Each time pressing the POWER SENSITIVITY button twice like double click the buz...

Page 12: ...ep sound and then returns to the detection sensitivity level indication When zero adjustment is not available the buzzer will sound and the detection sensitivity level remains displaying on the LCD 4...

Page 13: ...ode When it enters automatic gas exhaust mode the buzzer will sound once 60 will be displayed on the LCD and a countdown will start 59 58 Silent Mode No Operation Sound The alarm buzzer can be turned...

Page 14: ...d will be turned ON or OFF The alarm sound icon on the LCD will light buzzer ON or go out buzzer OFF Lighting the Backlight Tap the ZERO RESTART PUMP BACKLIGHT button to light up the backlight for 30...

Page 15: ...g ON the power several times there may be a problem with the sensor Request repairs Pump Error Error lamps flash Water or liquid may have been sampled or the inlet may be blocked Remove the water or l...

Page 16: ...unction properly and will not be able to detect correctly Attach the filter case securely If the filter case is loose water or other foreign matter may leak into the Gas Leak Detector If water or liqu...

Page 17: ...Turn the cap of the Drain Filter counterclockwise to remove together with the Gas Probe 2 Remove FE 106 Dust Filter and replace with a new filter 3 Attach the Drain Filter and reassemble Make sure to...

Page 18: ...en the side zipper 2 Open the battery lid of the back of the Gas Leak Detector and install two new batteries size AA alkaline as shown on the bottom of the compartment 3 Close the battery lid firmly 4...

Page 19: ...the alarm sound icon is being displayed and the alarm lamp red does not flash or the alarm buzzer does not sound contact your New Cosmos distributor Gas Probe Check the Gas Probe for any wear or damag...

Page 20: ...ng and coupling Gas Collector AT 5 20524430 For tubing and coupling Annealed Copper Tube AT 11 20524431 59060000 with tube For tubing secluded locations or devices Sampling Hose SH 4 05 20524531 Used...

Page 21: ...will not turn ON when the POWER SENSITIVY button is pressed The battery polarity is reversed Insert the batteries correctly Battery Replacement on page 16 Battery exhaustion Replace the batteries Disp...

Page 22: ...After examination of allegedly defective product return to New Cosmos with freight prepaid should the product fail to conform to this warranty customer s only remedy and New Cosmos s only obligation...

Page 23: ...g Pressure Range Atmospheric pressure 800 to 1100 hPa Operating Temperature and Humidity Range 0 to 40 degrees C Less than 85 RH with no condensation Dimensions Approx 38 W x 130 H x 32 D mm excluding...

Page 24: ...cted of a metal oxide semiconductor that is sintered in a ball on a platinum wire coil that functions as both a heater and electrode When combustible gas is absorbed by the surface of the metal oxide...

Page 25: ...23 MEMO...

Page 26: ...MEMO...

Page 27: ...MEMO...

Page 28: ...naka Yodogawa ku Osaka 532 0036 Japan Tokyo Branch New Cosmos Electric Co Ltd 2 6 2 Hamamatsu cho Minato ku Tokyo 105 0013 Japan Phone 81 3 5403 2715 Fax 81 3 5403 2710 Email e info new cosmos co jp U...

Reviews: