10
Figure 4-1 - Diagram of operation of AGUAstore with hot water heater AGUADENS 16 or 22
4.1 - Diagram of operation
WARNING! This storage tank must be used with a COSMOGAS hot water heater for the production of
DHW. Before proceeding with installation, the hot water heater’s installation, use and maintenance manual must
be read carefully.
The operating diagrams are shown below:
AGUAstore with
hot water heater model
AGUADENS 16
or
22
(See fig. 4-1).
4 - OPERATION
KEY to figure 4-1
1 - COSMOGAS hot water heater;
2 - Recirculation pump (responsibility of installer);
3 - Hot water heater hot water outlet;
4 - Gas inlet;
5 - Hot water heater cold water inlet;
6 - AGUAstore storage tank model;
7 - ----------;
8 - Storage tank sensor (from hot water heater);
9 - DHW uses;
10 - ----------;
11 - Domestic cold water inlet:
12 - ----------;
13 - ----------;
14 - ----------;
15 - ----------;
16 - ----------;
17 - ----------;
18 - ----------;
19 - ----------;
20 - Expansion tank (provision the responsibility of the installer);
21 - ----------;
22 - Remote control (on request);
23 - Solar control unit (on request);
24 - S2 bottom storage tank sensor (from solar control unit);
25 - Solar safety and charge group (on request);
26 - Solar panels (on request);
27 - ----------;
28 - ----------;
29 - ----------;
30 - ----------;
31 - Storage tank safety valve;
32 - Isolation valve;
33 - Valve to adjust flow rate (responsibility of installer);
34 - Anti-limescale water softener (responsibility of installer);
35 - Check valve (responsibility of installer);
36 - Cold water usage;
37 - Impurity filter (responsibility of installer);
38 - Pressure reducer (responsibility of installer);
39 - S1 solar panel sensor (from solar control unit);
40 - S3 top storage tank sensor (from solar control unit);
41 - Thermostatic mixer (responsibility of installer);
42 - Drain (responsibility of installer);