1  Safety 

•  Read the operating instructions before working on the pump.
•  These instructions are part of the product, are valid for all 

series named and describe how to use the product safely 
and correctly during all operating phases.

•  Installation of the pump may only be performed by qualified 

personnel.

•  Have all electrical work carried out by qualified electricians 

only.

•  Before carrying out any installation or maintenance work, 

disconnect pump from power supply and ensure it cannot 
be reconnected unintentionally.

•  Once installation work is complete, pass the instructions on 

to the end user. Keep the operating instructions complete, 
in a legible condition and permanently accessible.

•  Only operate the pump if it is in perfect technical condition; 

only use it as intended, staying aware of safety and risks, 
and adhering to the instructions in this manual. 

•  This circulator is suitable for drinking water only.

 

2  Safety information

DANGER!

 Immediate acute risk. Fatal or serious injury may 

occur.

WARNING!

 Potential acute risk. Fatal or serious injury may 

occur.

CAUTION!

 Potential hazardous situation. Light injury, damage 

to device may occur.

NOTE!

 Information, instruction.

Summary of Contents for CPB

Page 1: ...rpumpe High Efficiency HWR Pump Vysoce inn erpadlo na u itkovou vodu CPB CPBA de Einbau und Betriebsanleitung en Installation and operating instructions cz N vod k instalaci a obsluze G U T E S K L I...

Page 2: ...2 Fig 1 Fig 2 Fig 3 Fig 4 1 1 3 5 2 4...

Page 3: ...3 Fig 5 Fig 6 Fig 7...

Page 4: ...den CE CONFORMITY This product meets the applicable European directives and the complementary national requirements and standards Conformity has been proven The declaration of conformity can be retrie...

Page 5: ...5 DE Deutsch Seite 6 EN English Page 12 CZ esky Strana 18...

Page 6: ...alten und gegen Wiedereinschalten sichern Nach der Installation die Anleitung an den Eigent mer weiter geben Betriebsanleitung vollst ndig und lesbar halten und jederzeit zug nglich aufbewahren Die Pu...

Page 7: ...Elektr Anschluss 1 115 230V 50 60Hz Leistungsaufnahme 7 Watt Schutzart IP 42 Druckfestigkeit 10 bar 1000 kPa Temperaturfestigkeit 95 C Medientemperatur bis 75 C Umgebungstemperatur bis 40 C zul ssige...

Page 8: ...Rohrsystem vor Einbau durchsp len INFO Die Pumpe nur komplett einbauen bzw austauschen Motor und Pumpengeh use Die Montage des Motors auf ein Fremdpumpengeh use ist nicht m glich INFO Beim Pumpentyp C...

Page 9: ...zu einem wiederholten Anhalten und Wiederanlaufen des Rotors Erst bei Betrieb im luftfreien Medium l uft der Rotor ohne Unterbrechung VORSICHT Sachschaden durch Wasseraustritt Im Auslieferzustand ist...

Page 10: ...u kann der Rotor bei Bedarf entnommen werden Vor Ausbau des Pumpenkopfes siehe Schritte 8 und 9 im Kapitel 6 Absperrventile schlie en 10 St rungen und Abhilfema nahmen St rung Ursache Abhilfe Pumpe l...

Page 11: ...11...

Page 12: ...t cannot be reconnected unintentionally Once installation work is complete pass the instructions on to the end user Keep the operating instructions complete in a legible condition and permanently acce...

Page 13: ...30V 50 60Hz Power consumption 7 Watt Protection class IP 42 Compression strength 10 bar 1000 kPa Temperature resistance 95 C Max fluid temperature 75 C Max ambient temperature 40 C Permitted water har...

Page 14: ...Flush pipework before installation INFO Use the pump motor with the included pump housing only The pump motor does not fit to other pump housings in the market NOTE As to the COSMO CPBA version stop v...

Page 15: ...mbled shows a repeated start and stopping of the rotor A continuous pump run is possible within the vented recirculation system only CAUTION Damage to device caused by water extrusion As to the COSMO...

Page 16: ...purpose the rotor may be removed from the motor Close the stop valves before unscrewing the motor head see steps 8 and 9 in chapter 6 10 Faults and corrective measures Fault Causes Remedies Pump not...

Page 17: ...17...

Page 18: ...jist te proti op tovn mu zapnut Po instalaci p edejte n vod majiteli N vod k obsluze udr ujte kompletn a iteln a uschovejte jej v dy na p stupn m m st erpadlo provozujte pouze v technicky bezvadn m st...

Page 19: ...mno stv 650 l h Elektr p vod 1 115 230 V 50 60 Hz P kon 7 W Kryt IP 42 Pevnost v tlaku 10 bar 1000 kPa Teplotn odolnost 95 C Teplota m dia a 75 C Okoln teplota a 40 C Dovolen tvrdost vody neomezen Oc...

Page 20: ...sledku ne istot se m e erpadlo st t nefunk n Potrubn syst m p ed instalac propl chn te INFO erpadlo instalujte resp vym te jen jako celek motor a t leso erpadla Mont motoru na ciz t leso erpadla nen...

Page 21: ...mimo m dium vede k opakovan mu zastavov n a rozb h n rotoru Rotor b bez p eru en a p i provozu v m diu bez vzduchu POZOR V cn kody v d sledku niku vody Ve stavu p i dod n je uzav rac ventil otev en Ob...

Page 22: ...tor v p pad pot eby vyjmout P ed demont hlavy erpadla viz kroky 8 a 9 v kapitole 6 Zav ete uzav rac ventily 10 Z vady a opat en k n prav Z vada P ina N prava erpadlo neb P vod proudu je p eru en erpad...

Page 23: ...23...

Page 24: ...G U T E S K L I M A B E S S E R L E B E N COSMO GmbH Brandst cken 31 22549 Hamburg www cosmo info de Part Number 110101026 08 2016...

Reviews: