本製品を安全に使用していただくため、必ずお守りいただくことを説明しております。これら
の内容に反する使用法によるいかなる事故・損害についても当社では責任を負いかねます。

Please read this entire manual to fully understand and safety use of i-MyRun II. We will not 
be liable for any types of damages nor losses for usage against contents written in this 
manual.

警告

WARNING SIGN

注意

ATTENTION SIGN

禁止

PROHIBITION SIGN

感電注意

WARNING SIGN 
(Electricity)

指示を守る                    

本書に記載されている指示を守ってください。

Indicates instructions to follow.

マークの説明      Important user information

「死亡や重症を負うおそれがある内容」です。

Indicates a potentially hazardous situation, which 
if not avoided, will result in death or serious 
injury.

「軽傷を負うことや、製品の故障が発生するおそ

れがある内容」です。
Indicates a potentially hazardous situation, which  
if not avoided, may result in minor injury or 
equipment damage. 

「安全に使用するためにしてはいけない内容」です。

Indicates a situation not recommended for your 
safety reasons.

「感電のおそれがある内容」です。

Indicates a situation there is a fear of electric 
shock. 

2

i-MyRunⅡ核酸電気泳動システム取扱説明書̲B5.indd   2

i-MyRunⅡ核酸電気泳動システム取扱説明書̲B5.indd   2

2014/10/09   14:49:54

2014/10/09   14:49:54

Summary of Contents for i-MyRun II

Page 1: ...i MyRun II...

Page 2: ......

Page 3: ...N SIGN WARNING SIGN Electricity Indicates instructions to follow Important user information Indicates a potentially hazardous situation which if not avoided will result in death or serious injury Indi...

Page 4: ...l shock Do not use this product if outer damage cuased by strong shocks such as from being dropped as a re or electrical shock could result Do not operate this product nor unplug Power cable from the...

Page 5: ...bu er in it separate the Power supply rst before moving unless hold the Power supply and the tank rmly with both hands as electrode connectors will be stressed equipment damage or dropping of product...

Page 6: ...eave bu er in Gel electrophoresis tank for prolonged period as degradation of electrode could result Gel electrophoresis tank and Gel casting tray both have UV Ultraviolet light transparency though pr...

Page 7: ...Features Power supply Gel electrophoresis tank Gel electrophoresis tank cover Gel casting tray Combs Gel casting stand Power cable 1 1 Standard components 1 1 each 1 1 each 1 1 each 1 1 each 6 6 each...

Page 8: ...rom Gel electrophoresis tank Power supply will detach from the Gel electrophoresis tank by rotating towards it How to attach Power supply and Gel electrophoresis tank When attaching Power supply slide...

Page 9: ...ns 0 99 0 Timer settings from 0 99 minutes Gel electrophoresis will end when timer reaches 0 zero When timer is set to 0 zero will be displayed for continuous run mode 3 Voltage setting button 50 75 1...

Page 10: ...or 0 5 TAE bu er is recommended For preparation of 4 mm thickness agarose gel amount of 70 80 mL gel will be required For 4 mm thickness agarose gel 9 L 26 well comb or 18 L 13 well comb of sample ca...

Page 11: ...tore agarose gel you have prepared be sure to cover the gel with bu er after gently drawing out Comb s Wrap the gel in plastic wrap and store it under low temperature Remove Gel casting tray with agar...

Page 12: ...electrophoresis Please double check that RUN button lights up and air bubbles forming from platinum wires at both ends of the tank Performing gel electrophoresis for prolonged time under condition of...

Page 13: ...t taking out the gel from the tank if staining dye has been added into the agarose gel when preparing it Always wear a visor or approved goggles to help vision and to protect your eyes and skin from U...

Page 14: ...W 65mm H 240 mm L Gel electrophoresis tank UV light transparent resin Gel casting tray UV light transparent resin Gel electrophoresis tank cover UV light un transparent resin Not enough current in th...

Page 15: ...d strains tilts Make sure that agarose gel does not contain any air bubbles nor undissolved gel blocks Make sure that agarose gel is not too thin For preparation of 4 mm thickness agarose gel amount o...

Page 16: ...If observing the result through gel electrophoresis tank or tray try observing only the gel If the gel after gel electrophoresis has been left out for prolonged period nucleic acid bands may di use an...

Page 17: ...memo 16...

Page 18: ...i MyRun II e mail FAX 1 i MyRun II IMR2 001 FAX TEL e mail 17...

Page 19: ...1 2 3 4 18...

Page 20: ...0016 2 2 20 TEL 03 5632 9610 FAX 03 5632 9619 TEL 03 5632 9620 URL http www cosmobio co jp TOYO EKIMAE BLDG 2 20 TOYO 2 CHOME KOTO KU TOKYO 135 0016 JAPAN TEL 81 3 5632 9617 FAX 81 3 5632 9618 email...

Reviews: