Dedicated harnesses are available for your purchase.  Please 
see Optional Parts for details.

*

1  If the output of an external power supply is within the range 

of 4.5 - 12.5V, you do not need a current limiting resistor R.  If 
the output exceeds 12.5V, however, please connect the cur-
rent limiting resistor R.

To calculate a current limiting resistance value, please use the fol-
lowing equation.

R[

W

]=

Please wire carefully.  If you wire wrongly, the internal components 
of a unit may be damaged.

¡

Remote ON/OFF circuits (RC+ and RC-) are isolated from input, 
output and FG.

¿ 

-N (PBA10F, PBA15F, PBW15F, PBA30F, 

PBW30F,  PBA50F,  PBW50F,  PBA75F, 

PBA100F and PBA150F)

-

Option -N units come with a cover.

Appearance of Option -N units is different from that of standard 
units.  Please see External View for details.

Derating curve for Option -N units is different from that for stan-
dard units.  Please see 5.2 Derating Curve for details.

Only -24V type complies with UL508 standard (only Option -N 
units of 12V type of PBA50F, PBA75F, PBA100F and PBA150F 
comply with UL508 standard.  Application for compliance of 
PBA10F, PBA15F and PBA30F has been filed).

Safety agency approvals will be void if the cover is attached after 
the unit is ex-factoried.

¿ 

-N1 (PBA10F, PBA15F, PBW15F, PBA30F, 

PBW30F,  PBA50F,  PBW50F,  PBA75F, 

PBA100F and PBA150F)

-

Option -N1 units come with a dedicated DIN rail attachment.

-

Please contact us for details about appearance.

-

-Option -N1 units come with a cover (Option -N).

-

Each model has its own vibration and shock specifications.

¿ 

-V (PBA10F, PBA15F, PBW15F, PBA30F, 

PBW30F,  PBA50F,  PBW50F,  PBA75F, 

PBA100F and PBA150F)

Option -V units have connector for external potentiometer in-
stead of a built-in potentiometer.

Appearance of Option -V units is different from that of standard 
units.  Please contact us for details.

If power is turned on while CN5 is open, output voltage de-
creases significantly.

¿ 

-K (PBA100F/PBA150F/-3R3/-5 Only)

Option -K units have a remote sensing function.  Please note 
that this option is not available for all models.

-

Please contact us for details.

External views are different among models.

Unit type

Instruction Manual

A-44

PB

Unit type

Instruction Manual

A-45

PB

Fig.7.7 Example of using a remote ON/OFF circuit

Vcc-(1.1+Ri

X

0.005)

0.005

Fig.7.8 Power supply installed on a DIN rail

���

���

Fig.7.9 Upper view of option -V

Ri

 

RC (-)

RC (+)

2

1

 

 

*

1

R

SW

External Power 

Source

Remote ON/OFF connector (Optional)

Input Current

Inside of a Power 

Supply

Summary of Contents for PBA1000F

Page 1: ...bling and Installation A 40 A 35 A 35 A 35 A 35 A 36 A 36 A 36 A 37 A 38 4 1 Series Operation 4 2 Parallel Operation Master slave Operation 4 3 N 1 Parallel Redundancy Operation 5 1 Installation 5 2 D...

Page 2: ...output 12V 0 1A RC1 Remote ON OFF AUXG Auxiliary output GND N C No connection PG Alarm PGG Alarm GND Matching connecters and terminals on CN1 CN2 and CN3 Connector Housing Terminal Mfr CN1 CN2 CN3 S1...

Page 3: ...rcuit When you turn the power ON OFF repeatedly within a short period of time please have enough intervals so that the inrush current limiting circuit becomes operative When the switch of the input is...

Page 4: ...1 gives you only an estimate Please contact us if you need accurate numbers Output voltage Xrated output voltage 1 Please do not apply an external voltage of 0 7V or less or 3 0V or more There is more...

Page 5: ...ltage may dramatically fluctuate because of an imped ance of wiring and load conditions Please check and evaluate carefully before using the remote sensing function If the output voltage becomes unsta...

Page 6: ...High vary depending on models and conditions PBA300F and PBA600F less than 1 second PBA1000F and PBA1500F less than 10 second 2If the output voltage is turned off through a remote ON OFF cir cuit the...

Page 7: ...imum number of units you can use in parallel operation is 5 4 2 Parallel Operation Master slave Operation PBA10F PBA15F PBW15F PBA30F PBW30F PBA50F PBW50F PBA75F PBA100F and PBA150F You can use the po...

Page 8: ...PBW30F Input Voltage Derating Curve Input voltage derating curve is shown in Fig 5 2 PBA300F PAB600F PBA1000F and PBA1500F Ambient Temperature Derating Curve Derating curve depending on an ambient te...

Page 9: ...ting curve Unit type Instruction Manual A 41 PB Fig 5 3 Ambient temperature derating curve Ambient temperature C Load factor 80 70 80 90 100 30 40 50 60 70 71C 0 10 20 30 40 50 60 20 10 20 0 10 Fig 5...

Page 10: ...filter Examples of Constant Values of the External Noise Filter L1 0 45mH L2 0 45mH C1 0 1 F C2 0 1 F C3 0 1 F C4 4700pF C5 4700pF R1 2MW R2 2MW 6 Others 6 1 Output Current Monitor PBA300F PBA600F PB...

Page 11: ...ns Doing so may cause a failure F1 PBA600F PBA1000F PBA1500F Option F1 units have a longer life fan instead of a standard fan This option is not available for PBA300F Differences from standard version...

Page 12: ...PBW30F PBA50F and PBW50F 2 Matching Molex Connectors and Terminals for PBA75F PBA100F and PBA150F R PBA50F PBW50F PBA75F PBA100F and PBA150F You can control output ON OFF remotely in Option R units To...

Page 13: ...5F and PBA30F has been filed Safety agency approvals will be void if the cover is attached after the unit is ex factoried N1 PBA10F PBA15F PBW15F PBA30F PBW30F PBA50F PBW50F PBA75F PBA100F and PBA150F...

Reviews: