3 Temperature Measurement Point

LFP-14

5 Ground

LFP-17

4 Life expectancy and warranty

LFP-16

1 Function

LFP-13

2 Series Operation and Parallel Operation

LFP-14

1.1  Input voltage range
1.2  Inrush current limiting
1.3  Overcurrent protection
1.4  Overvoltage protection
1.5  Thermal protection
1.6  Output voltage adjustment range
1.7  Output ripple and ripple noise
1.8 Isolation
1.9  Reducing standby power

LFP-13
LFP-13
LFP-13
LFP-13
LFP-13
LFP-13
LFP-13
LFP-14
LFP-14

2.1  Series Operation
2.2  Parallel Operation

LFP-14
LFP-14

6 Peak loading

LFP-17

7.1  Outline of options
7.2 Others

LFP-18
LFP-20

7 Option and Others

LFP-18

Instruction Manual

AC-DC Power Supplies Open Frame/ Enclosed Type

LFP-13

June 26, 2020

Summary of Contents for LFP100F

Page 1: ...ge protection 1 5 Thermal protection 1 6 Output voltage adjustment range 1 7 Output ripple and ripple noise 1 8 Isolation 1 9 Reducing standby power LFP 13 LFP 13 LFP 13 LFP 13 LFP 13 LFP 13 LFP 13 LF...

Page 2: ...drops to a certain extent the output becomes hic cup so that the average current will also decrease 1 4 Overvoltage protection An overvoltage protection circuit is built in If the overvoltage pro tec...

Page 3: ...75 89 89 0 Io 50 89 89 C Convection 75 Io 100 85 86 50 Io 75 89 89 0 Io 50 89 89 D Convection 75 Io 100 84 76 50 Io 75 89 86 0 Io 50 89 89 E Convection 75 Io 100 81 89 50 Io 75 86 89 0 Io 50 87 89 F...

Page 4: ...more 8years B Convection Ta 35C or less 10years or more 10years or more Ta 45C 10years or more 10years or more C Convection Ta 35C or less 10years or more 10years or more Ta 45C 10years or more 6years...

Page 5: ...emperature year Warranty Io 75 75 Io 100 A Convection Ta 40C or less 5years 5years Ta 50C 5years 3years B Convection Ta 35C or less 5years 5years Ta 45C 5years 3years C Convection Ta 35C or less 5year...

Page 6: ...dard untis Please contact us about the detail LFP300F I O Connector Mating connector Terminal CN1 7 1565036 6 1 1123722 8 Chain 1123721 1 Loose 1318912 1 CN2 1 1123723 6 1 1123722 6 Chain 1123721 1 Lo...

Page 7: ...t limiting resistor R If the output exceeds 12 5V however please connect the cur rent limiting resistor R To calculate a current limiting resistance value please use the fol lowing equation R W Vcc 1...

Page 8: ...cessary to use wires which rated voltage is 600V or more 4 It must be used with the external capacitor unit CR HUT 5 For more information about the external capacitor unit and har ness please refer to...