-S
-
-SN
-
-S indicates a type with chassis, and -SN indicates a type with
chassis and cover (Refer to external view).
Please contact us about the detail of derating curve.
-
Please contact us about the detail of LFP300F.
¿
-SNF (LFP300F-24-TY)
-
In option -SNF, the cover, chassis and cooling fan are added.
-
The appearance of option -J and -J1 models are defferent from
the of standard appearance. Please contact us about the detail.
-
Oil and other chemical liquid splashing environment may cause
the performance degradation and failure.
¿
-R
-
You can control output ON/OFF remotely in Option -R models.
To do so, connect an external DC power supply and apply a
voltage to a remote ON/OFF connector, which is available as
option.
Model Name
Built-in
Resistor
Ri [
W
]
Voltage between RC (+)
and RC (-) [V]
Input
Current
[mA]
Output ON Output OFF
LFP100F, LFP150F
LFP240F, LFP300F
780
4.5 - 12.5
0 - 0.5
20max
Ri
RC (-)
RC (+)
2
1
*
1
R
SW
External Power
Source
Remote ON/OFF connector (Optional)
Input Current
Inside of a Power
Supply
Fig.7.1 Example of using a remote ON/OFF circuit
-
Dedicated harnesses are available for your purchase. Please
see Optional Parts for details.
*
1 If the output of an external power supply is within the range
of 4.5 - 12.5V, you do not need a current limiting resistor R. If
the output exceeds 12.5V, however, please connect the cur-
rent limiting resistor R.
To calculate a current limiting resistance value, please use the fol-
lowing equation.
R[
W
]=
Vcc-(1.1+Ri
X
0.005)
0.005
*
Please wire carefully. If you wire wrongly, the internal components
of a unit may be damaged.
¡
Remote ON/OFF circuits (RC+ and RC-) are isolated from input,
output and FG.
¿
-R2
-
The usege is the same as option -R, please refer to Option -R.
-
Reducing standby power is possible by OFF signal of the re-
mote control.
-
Start up time by ON signal in remote control is 350ms(typ).
-
The latch condition in overvoltage protection is removed by tog-
gling ON/OFF signal of remote control.
-
Standby power
LFP100F, LFP150F, LFP240F
0.2Wtyp (AC100V), 0.7Wtyp (AC200V)
LFP300F
0.25Wtyp (AC100V), 1.1Wtyp (AC200V)
¿
-T (LFP240F, LFP300F)
-
Option -T models have vertically positioned screws on a termi-
nal block.
-
Please contact us for details about appearance.
FG
AC (N)
AC (L)
-V
+V
Fig.7.2 Example of option -T
¡
The screw can be held to terminal block by inserting and lifting the
screwdriver from the side of terminal block.
+ screwdriver
terminal block
screw
f
5.5MAX
Fig.7.3 lifting method
¿
-T1 (LFP300F)
-
Option -T1 models have horizontally positioned screws on a ter-
minal block.
-
Please contact us for details about appearance.
FG
AC (N)
AC (L)
-V
+V
Fig.7.4 Example of option -T1
AC-DC Power Supplies Open Frame/ Enclosed Type
Instruction Manual
LFP-19
June 26, 2020