background image

(a)                           (b)                              (c)

ON

POWER

RC2

RC3

AUX

OFF

-S

typ

12V

150

W

2.2k

W

ON

POWER

RC2

RC3

AUX

OFF

-S

typ

12V

150

W

2.2k

W

typ

12V

150

W

2.2k

W

ON

POWER

RC2

RC3

AUX

OFF

-S

Fig.3.3 RC2

-

RC3 connection example

¡

Make sure that sink current of output side remote ON/OFF circuit 
should be less than 12mA.

(3) Auxiliary power supply for remote ON/OFF(AUX)

¡

AUX is built in for operating the output side remote ON/OFF 

(RC2

-

RC3).

If AUX is not used for RC2

-

RC3, AUX can be used for IOG or 

TMP signal output by opto coupler.

¡

Short protection resistance(2.2k

W

) is built in.

Output voltage decreases as the output current increases.
(AUX voltage at open circuit: 15V max)

3.6 Remote sensing

(1) When the remote sensing function is not in use

¡

When the remote sensing function is not in use, it is necessary to 
confirm that pins are shorted bS & +VOUT and between 
-S & -VOUT.

¡

Wire bS & +VOUT and between -S & -VOUT as short as 
possible.
Loop wiring should be avoided.
This power supply might become unstable by the noise coming 
from poor wiring.

(2) When the remote sensing function is in use

¡

Twisted-pair wire or shield wire should be used for sensing wire.

¡

Thick wire should be used for wiring between the power supply 
and a load.
Line drop should be less than 0.5V.
Voltage bVOUT and -VOUT should remain within the 
output voltage adjustment range.

¡

If the sensing patterns are short, heavy-current is drawn and the 
pattern may be damaged.
The pattern disconnection can be prevented by installing the pro-
tection parts as close as a load.

+S

-S

+VOUT

-VOUT

OUT

Co

Load

Short at pin root

+

Fig.3.4 Connection when the remote sensing is not in use

+S

-S

+VOUT

-VOUT

OUT

Load

Wire as close as possible

Co

+

Fig.3.5 Connection when the remote sensing is in use

3.7 Adjustable voltage range

¡

Output voltage is adjustable by the external potentiometer or by 
applied voltage externally.
The adjustable range is 60 - 110% of the rated output voltage.

¡

When the output voltage adjustment is used, note that the over-
voltage protection circuit operates when the output voltage sets 
too high.

(1) Adjusting method by external resistor

¡

By connecting the external potentiometer(VR1) and resistors(R1, 
R2), output voltage becomes adjustable, as shown in Fig.3.6, rec-
ommended external parts are shown in Table 3.3.

¡

The wiring to the potentiometer should be as short as possible.
The temperature coefficient becomes worse, depending on the 
type of a resistor and potentiometer. Following parts are recom-
mended for the power supply.
Resistor  

 Metal film type, coefficient of less than 

100ppm/

C

Potentiometer   Cermet type, coefficient of less than 

300ppm/

C

¡

When the output voltage adjustment is not used, open the TRM 
pin and VB pin respectively.

RB

10k

W

RA

15k

W

Reference

voltage 2.5V

VR1

R2

R1

TRM

VB

+S

+VOUT

-VOUT

-S

Control Amp.

of rated

voltage

Fig.3.6 Output voltage control circuit

DC-DC Converters Bus Converter

-

Power Module Type

Instruction Manual

DBS-16

June 26, 2020

Summary of Contents for DBS100A

Page 1: ...Thermal detection Thermal protection DBS 15 3 4 Inverter operation monitor DBS 15 3 5 Remote ON OFF DBS 15 3 6 Remote sensing DBS 16 3 7 Adjustable voltage range DBS 16 3 8 Isolation DBS 17 3 Function...

Page 2: ...external noise filter and a decoupling capacitor CY for low line noise and for stable operation of the power supply Install a correspondence filter if a noise standard meeting is re quired or if the...

Page 3: ...pins Table 2 2 Recommended capacitance Co F Model DBS100A DBS150A DBS200B DBS400B DBS700B Output voltage V 3 3 x 2200 6800 x 5 2200 2200 4700 x 7 5 x 2200 4700 x 12 1000 1000 2200 2200 13 8 1000 x x...

Page 4: ...hiccup operation of power supply 3 2 Overvoltage protection The overvoltage protection circuit is built in The DC input should be shut down if overvoltage protection is in operation The mini mum inter...

Page 5: ...current is drawn and the pattern may be damaged The pattern disconnection can be prevented by installing the pro tection parts as close as a load S S VOUT VOUT OUT Co Load Short at pin root Fig 3 4 C...

Page 6: ...ty for equipment In parallel operation the maximum operative number of units is 11 Table 3 3 Recommended value of external potentiometer resistor No Adjustable range Number of unit External parts valu...

Page 7: ...ration sensing wires should be connected between each units for the muster connection to a load Output current should be 10 or more of the total of the rated output current in parallel operation If le...

Reviews: