WPBX00 PRO MAN
Page 2
SYSTEM SECURITY CODE
The default System Security Code is 828828.
To change the System Security Code:
(a) Enter Programming and select Setup-Set-
tings-MBS-Change SSC.
(b) After selecting Change SSC, enter the new
password (min of 1 number, max of 6 numbers)
and confirm new password. Enter OK to ac-
cept or CANCEL to exit the window and can-
cel the new password. The password may be
changed again before exiting the programming
software without entering the new password.
(c) Once this password is changed, the pro-
gramming can only be accessed by the new
password or universal password which is
288288.
(d) The MBS will allow 3 attempts to enter the
correct SSC password before closing the pro-
gramming.
DISTRIBUTOR PASSWORD
The default Distributor Password is 288288.
The Distributor Password cannot be changed.
AUTHENTICATION PASSWORD
The default Authentication Password is
12345678. To change the Authentication
Password:
(a) Enter Programming and select Setup-Set-
tings-MBS-Change AC.
(b) After selecting Change AC, enter the new
password (min 1 number, max 8 numbers) and
confirm new password. Enter OK to accept the
change or press CANCEL to exit the window
and cancel the new password.
(c) The universal password does not ap-
ply to the Authentication code. The entire
password must be reset. Refer to section
4.48.
GENERAL RULE
2.05 When viewing any programming
screens, the shaded items are informative
items and cannot be changed. The white items
are changeable items. In all screens, OK will
accept the change and CANCEL will exit the
window.
3.
SOFTWARE INSTALLATION
3.01 Programming of the Compass
can be done through the PC using a RS232
interface. The software is shipped with each
system and should be copied to the PC local
directory.
3.02 Before initializing the software pro-
gramming, connect the RS232 cable to the
Master Base Station PC setup port and also
to the COM port of the PC.
3.03 Run the setup program by executing the
file PABXCFG.EXE.
3.04 Check to see what COM port is being
used on the PC. If the correct COM port is not
selected in the programming, then select the
correct port and press OK to start the connec-
tion process again. When the COM port is
correct, the MBS version is then displayed.
3.05 Compass PC setup software port set-
tings default to COM 1 at a baud rate of 19200
bps.
Compass software port settings
must match PC COM port settings.
To
change settings, find the file named pbx-set.ini
and modify the port settings to 9600 bps
(needed for MBS).