Start view
When K5 ES HP PX starts up, two options appear for
the user on the display:
Start:
Starts the machine with standard settings,
continuous operation with maximum capacity.
Previous settings such as use of sensor control, timer
etc.
Resume:
The machine resumes operation with the
same settings that previously applied.
If the user did not press the stop button before the
power was interrupted the last time the machine was
used, the machine will automatically resume operation
when the timer has counted down to zero.
The countdown can be stopped by pressing the Stop
button, which then switches the machines to standby
until it is started manually.
Normal start
Start after power cut
–
automatic resumption of operation
Standard view
When K5 ES HP PX is in operation, the machine can
always be stopped (set to standby) using the middle
button below the display.
When the machine is running in a control mode instead
of in manual mode, the setpoint (which is marked with
black background in the middle of the screen) can be
increased or decreased using the negative (-) and
positive (+) buttons.
When the compressor has stopped, the start is delayed
for at least 120 seconds. The remaining time until start
appears in the round circle to the left.
Also shown here is whether the machine is defrosting
and if it has stopped and gives an alarm for too high or
too low ambient temperature.
In the event of a dehumidification process stoppage,
the fan runs-on for post cooling for 120 seconds.
Standard view graphics. The machine is