© Corroventa Ltd.
2017.07
12 (27)
an external temp. and RH sensor. If the machine
is not already connected to the network, the
machine asks whether to create a network.
If there are several sensors in the network and if
the <All> option has been selected (instead of a
single sensor, e.g. RHT61) the machine works on
the "worst case scenario" and runs for as long as
any of the sensors detects that the humidity is
above the setpoint.
If the machine selects a mode other than MAN,
the user will note that the setpoint can be set.
When the setpoint has been reached, drying
stops automatically. If the humidity later rises
above the setpoint again, drying resumes
automatically.
Hysteresis
When one of control modes; RH, DP or X is
selected, a symbol and a hysteresis value
appears to the right of the display.
The symbol shows the setpoint value's position
in the operation range as below.
↕
- centre
↓
- bottom
↑
- top
Capacity mode
The drying capacity of K3 ES HP can be optimised
for a given work task and situation with three
different operating modes.
When setting MAX (maximum) the machine
works to remove as much water as possible. If
the machine's total power is not required, it can
instead be set to ECO (eco-mode) where the
energy consumption per litre of removed water
is minimised.
For localised water damage where the dry air
quantity is not required, the machine can be set
to ΔX (ΔX mode). In this mode, the machine
produces a smaller amount of even drier air that
further accelerates the drying process.
MAX
For maximum capacity.
•
High fan speed
•
Min temp 9°C
•
Max temp 38°C
•
RH min 0 %