Start view
When K3 ES HP starts up, two options appear for
the user on the display:
Start:
Starts the machine with standard settings,
continuous operation with maximum capacity.
Previous settings such as use of sensor control,
timer etc.
Resume:
The machine resumes operation with
the same settings that previously applied.
If the user did not press the stop button before
the power was interrupted the last time the
machine was used, the machine will
automatically resume operation when the timer
has counted down to zero.
The countdown can be stopped by pressing the
Stop button, which then switches the machines
to standby until it is started manually.
Normal start
Start after power cut
–
automatic resumption of operation
Standard view
When K3 ES HP is in operation, the machine can
always be stopped (set to standby) using the
middle button below the display.
When the machine is running in a control mode
instead of in manual mode, the setpoint, which
is marked with black background in the middle
of the screen, can be increased or decreased
using the negative (-) and positive (+) buttons.
When the compressor has stopped, the start is
delayed for at least 120 seconds. The remaining
time until start appears in the round circle to the
left.
Also shown here is whether the machine is
defrosting and if it has stopped and gives an
alarm for too high or too low ambient
temperature.
In the event of a dehumidification process
stoppage, the fan runs-on for post cooling for
120 seconds.