6-12
Constriction
Contaminated electrodes.
The arc burns irregularly.
Clean electrodes.
Fusion current too high.
Reduce in steps of 0.2 to
0.3 mA.
Autofeed too small.
Increase in steps of 1
µ
m.
Pre-fusion time too long.
Change only under extraordi-
nary circumstances.
Reduce in steps of 0.05 s.
Pre-fusion current too high.
Change only under extraordi-
nary circumstances.
Reduce in steps of 0.1 mA
Z-gap too wide.
Reduce Z gap in steps of
0.5
µ
m (do not set below
3
µ
m).
Enlargement
Autofeed too large.
Reduce in steps of 1
µ
m.
Symptom
Possible Cause
Remedy