STANDARD RECOMMENDED PROCEDURE 003-333 | ISSUE 9 | 

March

 2012 | PAGE 3 OF 6

3.5.  Lifting precautions

CAution: 

The Optical Splice Enclosure weighs over 

50 pounds. Two people are required to move or lift it into 

position.

4. 

mountinG

The enclosure ships with the mounting brackets attached in the location shown to mount the enclosure:

• 

on the wall,

• 

onto T-slot rails

• 

or into a 23-inch utility rack with frontal projection.

4.1.  Wall-mounting

importAnt: 

Make sure there is adequate space above 

and below the unit to route cables. Do not 

violate the minimum bend radius for any 

cable being installed. If you are installing a 

pass-through kit, maintain between 0.8 to 

2 inches between the two units.

step 1: 

choose a dry, vertical surface on 

which to mount the cabinet. The type 

of hardware used is dependent on 

the mounting location; wall anchors 

may be required for adequate support 

on sheetrock walls. Wall-mounting 

hardware is not provided.

step 2: 

Using the mounting template provided, 

mark the locations for the six mounting 

screws.

step 3: 

Leaving a 1/8-inch gap behind the 

screw head, install the two top mounting screws in the wall using the distances shown.

step 4: 

hang the unit on the two screws through the upper holes in the mounting brackets. Tighten 

the screws against the brackets.

step 5: 

Install the remaining screws in the lower holes in the brackets and tighten securely.

4.2.  t-slot mounting

T-slot rack mounting kits are purchased separately. refer to the accessories section of this instruction 

for part number information. Follow the instructions provided with the kit.

22.32

5.11

7.00

14.00

5.11

TPA-4082