STANDARD RECOMMENDED PROCEDURE 003-737 | ISSUE 4 | MAy 2015 | PAGE 4 OF 25
• Select an appropriate site per your design plan and follow standard local practices for
installation of the enclosure. The mounting location should be able to withstand the weight of
a fully loaded enclosure.
2. Materials and Tools Required
2.1 Materials
Mounting hardware to attach the enclosure to the wall is not provided. The hardware used is
dependent upon the surface to which the enclosure is being installed; the appropriate hardware
may be purchased from a local hardware store.
2.2 Tools
To install the enclosure, the following tools may be required:
• Hoist or lifting device capable of lifting at least 150 pounds (largest enclosure’s weight,
including packaging)
• Forklift or handtruck
• 216B tool or a 7/16-in nutdriver (for entry into the interior of the enclosure)
• Crescent wrench
• 9/16-in nut driver or socket
• 3/4-in nut driver or socket
• Phillips-head screwdriver
• Dry-process connector cleaning supplies
Depending upon the fiber and splicing configurations required for your application, the following
tools may be required to install the enclosure:
• Drill and drill bits
• Lint-free wipes
• Appropriate hardware (if wall mounting) for the wall-mount surface material
• Isopropyl alcohol
• Flat-tipped screwdriver
• Fiber stripping tools
• Splicing equipment and supplies
2.3 Auxiliary Equipment
There is no auxiliary equipment required to install the enclosure. If the enclosure is not full
to capacity, additional products may be installed to expand the customer connections. Refer
to the section, Growth, for details on expanding the capacity. Contact a Corning customer
service representative to order additional products in the configuration required by your network
installation plan.
3. Components and Shipping Container Contents
Figure 2 provides a pictorial description of the enclosure and its components.
• Packing List of Shipping Container Contents:
•
(1) OptiTect™ GEN III Local Convergence Point enclosure, prestubbed with distribution
and feeder cables in lengths specified by the customer (other configurations available)
•
(1) Installation instruction (SRP 003-737)
•
(1) Bag with extra adapter and connector dust caps
•
Wallmount kit (p/n 07-000867-001) including mounting brackets and hardware