Installation Manual | CMA-794-AEN | Page 7
Power
Max Distance (meters) @ AWG
12
14
16
78 W
778
467
295
88 W
689
414
261
96 W
632
379
239
98 W
619
372
235
Note: The maximum power consumption is 98 W when N2 has 8 PA modules operating at maximum
output power.
Class 2 Installation for North America area (maximum input power is 100 W):
Pn = 78 W
Power consumption of N2RU
Pw = 22 W
If N2 consumes 78 W then 22 W is
dissipated in the wire (Pw)
Pin = Vin*Iin = 100
W
Pin = 100 W max for class 2 installation
Rw = Pw/Iw2 =
6.8992
Rw = resistance of the wire
Vin = 56 V
Voltage of N2 PSU
Rw = Rd*D
D = distance of the wire (total length of
return cable)
Rd = resistance per meter of the wire
Iin = Pin/Vin =
1.786
Iin = Max injected current to not exceed
100 W
Cable
type
Voltage Drop
D=Rw/Rd (meters)
Max Fiber Distance (meters)
ohms/meter
2x distance between PSU and N2RU (there and back)
Distance between PSU and N2RU
12 AWG
0.00557
1239
619
14 AWG
0.00928
743
372
16 AWG
0.0147
469
235
Power
Max Distance (meters) @ AWG
12
14
16
78 W
619
372
235
88 W
338
203
128
94 W
169
101
64
98 W
56
34
21
The cable connector diagram is below
Figure 2.
Cable Connector Diagram