Standard Recommended Procedure 003-809 | Issue 7 | May 2017 | Page 2 of 6

2.4 

Ladder Rack Mounting Kit 4U (EDGE-BKT-LR-4RU)

• 

(1) Bottom plate / (2) omega brackets and (2) support  

bars preinstalled 

 

3. 

Tools and Materials Required

• 

Phillips screwdriver 

 

 

 

4. 

Kit Preparation

Before installing the kit into the wire tray or ladder rack, determine the number and size of the housings to be 

installed into the kit. Housing installation begins at the top of the kit.

2U Mounting Kit accepts:

4U Mounting Kit accepts:

(1) EDGE-02U

(1) EDGE-04U

(2) EDGE-01U

(2) EDGE-02U
(4) EDGE-01U
(2) EDGE-01U and (1) EDGE-2U

Step 1: 

If less than the full capacity of housings will be installed into the kit, move the support bars from 

their factory-installed positions so that they are positioned just below the lowest housing that will be 

supported.

Step 2: 

Install the kit into the wire tray or ladder rack as described in Section 5 or 6.

Step 3: 

Then mount the housings, beginning at the top of the kit. Ensure that the lowest housing rests on the 

support bars.

Figure 1