User Manual v1.0
Corning Restricted and Confidential Proprietary - Controlled content
BWS Draft2 LPR UM - 29-DEC-2019| September 2019
|Page 18 of 29
2.
General System Specifications and Requirements
2.1
Environmental and Regulatory Specifications
2.1.1
Temperature and Humidity
The environmental specifications listed below are relevant to all Corning BWS™ solution devices.
Table 5: Temperature and Humidity Specifications
Operating
Storage
Temperature
0C to 40°C
-40°C to 70°C
Humidity
Humidity 5% to 95%, non-
condensing
Humidity 5% to 95%, non-
condensing
2.1.2
Safety and Regulatory Approvals
The safety and regulatory specifications listed below are relevant to all
Corning BWS™ solution devices.
Table 6:
Safety and Regulatory Approvals
Regulation/
Standard Category
Approval
Laser Safety
FDA/CE 21 CFR 1040.10 and 1040.11 except for
deviations pursuant to Laser Notice No.50 and IEC
60825-1
EMC
FCC 47 CFR Part 15 Subpart B
ESD
IEC 61000-4-2
Safety compliance
IEC 62368-1/ cTUVus
2.2
Power Specifications
2.2.1
Power Input and Consumption
Table 7:
Units Power Consumption
Unit
Power Input
Power Consumption for Full
Chassis
LPR
AC power source: 100 to 220 V AC
DC power source: 48 V DC