background image

4

5

Table of Contents

 
  1. Introduction   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
  2. Work Safety Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
  3. Limitations of Use   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
  4. Turning On the Pipet Controller   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
  5. Aspirating and Dispensing Liquids  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
  6. Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
  7. Replacing the Filter   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
  8. Charging the Battery   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
  9. Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10. Components   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
11. Ordering Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
12. Spare Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
13. Product Disposal   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10

1. Introduction

The Axygen®MotoPet® pipet controller is a device intended for pipetting liquids with the 

use of measuring pipets. It can work with all types of glass or plastic pipets in the volume 

range from 0.5 mL to 100 mL.
Two dispense modes permit selection of dispensing intensity depending on the user’s 

needs. The selected setting of the pipet controller mode is shown on the display (Figure 1E) 

Figure 1 shows the external parts of the pipet controller with a description of the materials 

used. Display indicators are shown in Figure 2. 

2. Work Safety Instructions

 WARNING! Risk of injury

CAUTION: Risk of damage to the device or errors in pipetting of liquids

Before starting the work with the pipet controller every user should read these operating 

instructions carefully. 

CAUTION:

• Using the device inconsistently with the operating instructions may result in damaging 

the device.

• The device should be maintained only at an authorized service center, otherwise the 

manufacturer will be relieved from any liability under the warranty.

• Only original spare parts and accessories, recommended by the manufacturer, shall be used.
• Only the original charger, supplied by the manufacturer, shall be used for charging the 

batteries.

• In case of incorrect functioning of the pipet controller, work shall be stopped. The device 

shall be cleaned according to section 9 and sent for repair to an authorized service center.

• In the case of mechanical damage to the casing, the device shall be immediately sent for 

repair to an authorized service center.

• The use of excessive force during work shall be avoided.

WARNING!

• While working with the pipet controller general safety regulations regarding risks related 

with laboratory work should be observed. Protective clothing, goggles, and gloves should 

be worn.

• The pipet controller shall be used only for measuring liquids in conditions specified by 

the manufacturer, which are limited due to the chemical and mechanical resistance of 

the device, as well as the user safety.

• The information and instructions provided by the manufacturers of the reagents must 

be observed.

3. Limitations of Use

• The pipet controller should not be used for measuring substances, the vapors of which 

damage the following plastics: PP, SI, EPDM, POM.

• The pipet controller should not be used in an environment where explosion risk is present.
• Flammable liquids should not be measured, in particular substances with flash-point 

below 0°C (ether, acetone).

• The pipet controller should not be used for drawing acids with a concentration above 1 mol/L.

Summary of Contents for Axygen MotoPet

Page 1: ...Axygen MotoPet Pipet Controller Instruction Manual ...

Page 2: ... PP D Dispense mode switch PP E Display F Nose piece PP G Pipet holder SI H Membrane filter PP PTFE J Connector gasket SI K Battery cover PP L Charger 9V EU US UK AU Input 100 240V 50 60Hz 0 3A Output AC DC 9V 230mA Battery type NiHM M Charging base station N Bench stand P Wall mount PP Polypropylene PTFE Polytetrafluoroethylene SI Silicone Casing PP ...

Page 3: ...rom any liability under the warranty Only original spare parts and accessories recommended by the manufacturer shall be used Only the original charger supplied by the manufacturer shall be used for charging the batteries In case of incorrect functioning of the pipet controller work shall be stopped The device shall be cleaned according to section 9 and sent for repair to an authorized service cent...

Page 4: ...roller the device should be sent to the nearest authorized service center The pipet controller should not be used for drawing solutions with a temperature above 50 C The pipet controller should be operated in the temperature range from 10 C to 35 C The pipet controller is suitable for general laboratory use only It must be used only by personnel who know the health risks associated with the substa...

Page 5: ...ten details including the precise specification of solutions used and the type of laboratory in which the device was used should be sent with the product 7 Replacing the filter Note The work safety instructions given in section 2 should be observed when disassembling the pipet controller The filter replacement is necessary if drawing efficiency deterioration is observed The direct reason may be a ...

Page 6: ...uipment WEEE provided with the products and available at the following link www corning com weee The crossed out wheeled bin symbol is printed in the product instruction manual and on the packaging to indicate that in accordance with the requirements of Directive 2006 66 EC of 6th September 2006 on batteries and accumulators and waste batteries and accumulators batteries must be disposed of accord...

Page 7: ... EUROPE France t 0800 916 882 f 0800 918 636 Germany t 0800 101 1153 f 0800 101 2427 The Netherlands t 020 655 79 28 f 020 659 76 73 United Kingdom t 0800 376 8660 f 0800 279 1117 All Other European Countries t 31 0 20 659 60 51 f 31 0 20 659 76 73 LATIN AMERICA grupoLA corning com Brasil t 55 11 3089 7400 Mexico t 52 81 8158 8400 Corning Incorporated Daniszewska 4 03 230 Warsaw www corning com li...

Reviews: