29
SGHNX Series
REVISION # 0000
DATE: 03/07/2017
Reference
SGH series terminal connections
CN2
1
2
3
4
7
8
9
10
23
24
P5
P6
E5
E6
Control Station
Push Button
+
-
External Interlock
Timer Defeat Photo eyes
or IR sensing
edge
ELR sensing
edge
Stop Open Close Com
Close
warning
signal
24VDC
Jump when no
external interlock
is connected.
Control panel is wired with momentary pressure open and constant pressure close.
A one-second delay on reverse is standard.
When the door is closing, pushing the “Open” or “Stop” button will stop the door from moving.
When the door is closing, the radio control transmitter can stop and reverse the door at anytime.